Laserfiche WebLink
L15:15 <br />LIQUID SENSOR SETUP <br />TRI—STATE (SINGLE FLOAT) <br />— — — — — — — — — — — — <br />CATEGORY : OTHER SENSORS <br />T 2:87 <br />PRODUCT CODE 2 <br />L 1:87 ANNULAR <br />THERMAL COEFF :.000700 <br />TRI—STATE (SINGLE FLOAT) <br />TANK DIAMETER 119.80 <br />CATEGORY : ANNULAR SPACE <br />L16:16 <br />TANK PROFILE 4 PTS <br />TRI—STATE (SINGLE FLOAT) <br />FULL VOL 15104 <br />CATEGORY : OTHER SENSORS <br />89.9 INCH VOL 12340 <br />59.9 INCH VOL 7589 <br />L 2:91 ANNULAR <br />30.0 INCH VOL 2843 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING : 2.0 <br />L 3:87 STP SUMP <br />R 1:87 RELAY <br />TYPE: <br />HIGH WATER LIMIT: 2.5 <br />TRI—STATE (SINGLE FLOAT) <br />STANDARD <br />CATEGORY : STP SUMP <br />NORMALLY CLOSED <br />MAX OR LABEL VOL: 15104 <br />OVERFILL LIMIT 90 <br />TANK #: 2 <br />13593 <br />L 4:91 STP SUMP <br />HIGH PRODUCT 95% <br />TRI—STATE (SINGLE FLOAT) <br />14348 <br />CATEGORY : STP SUMP <br />LIQUID SENSOR ALMS <br />DELIVERY LIMIT 10%o <br />L 3:FUEL ALARM <br />1510 <br />L 5:FUEL ALARM <br />LOW PRODUCT 500 <br />L S:DISP 1-2 <br />TRI—STATE (SINGLE FLOAT) <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />LEAK ALARM LIMIT: 99 <br />CATEGORY :'DISPENSER PAN <br />L 8:FUEL ALARM <br />SUDDEN LOSS LIMIT: 99 <br />L 3:SENSOR OUT ALARM <br />TANK TILT 0.00 <br />L 5:SENSOR OUT ALARM <br />PROBE OFFSET 0.00 <br />L 6:SENSOR OUT ALARM <br />L 6:DISP 3-4 <br />TRI—STATE (SINGLE FLOAT) <br />L 7:SENSOk OUT ALARM <br />L $:SENSOR OUT ALARM <br />SIPHON MANIFOLDED TANKS <br />CATEGORY : DISPENSER PAN <br />L 3:SHORT ALARM <br />TO: NONE <br />L 5:SHORT ALARM <br />LINE MANIFOLDEU TANKS <br />L 6:SHORT ALARM <br />T#: NONE <br />L 7:SHORT ALARM <br />L 7:DISP 5-6 <br />TRI—STATE (SINGLE FLOAT) <br />L B:SHORT ALARM <br />LEAK MIN PERIODIC: 0% <br />CATEGORY : DISPENSER PAN <br />ISD SITE ALARMS <br />• 0 <br />ISD GROSS PRES FAIL <br />PERIODIC TEST TYPE <br />ISD DEGRD PRES FAIL <br />STANDARD <br />!SD VAPOR LEAK FAIL <br />PERIODIC TEST FAIL <br />L 8:DISP 7-8 <br />TRI—STATE (SINGLE FLOAT} <br />ISD VP PRES FAIL <br />ALARM DISABLED <br />CATEGORY : DISPENSER PAN <br />ISD HOSE ALARMS <br />ALL:FLOW COLLECT FAIL <br />GROSS TEST FAIL <br />ALARM DISABLED <br />R 2:91 RELAY <br />PER TEST AVERAGING: OFF <br />L 9:9 <br />TRI—STATE (SINGLE FLOAT} <br />TYPE: <br />STANDARD <br />CATEGORY OTHER SENSORS <br />NORMALLY CLOSED <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />TANK #: 1 <br />L1010 <br />DELIVERY DELAY 5 MIN <br />TRI—STATE {SItVGLE FLOAT} <br />LIQUID SENSOR ALMS <br />PUMP THRESHOLD : 10.00% <br />CATEGORY OTHER SENSORS <br />L 4:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />111:11 <br />TRI—STATE (SINGLE FLOAT) <br />L B:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />CATEGORY : OTHER SENSORS <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L12:12 <br />TkI—STATE {SINGLE FLOAT} <br />L 4:SHORT ALARM <br />L :SHORT ALARM <br />5:SHORT <br />CATEGORY : OTHER SENSORS <br />L ALARM <br />LEAK TEST METHOD <br />1. 7:SHORT ALARM <br />_ <br />TEST ON DATE ALL TANK <br />L 8:SHORT ALARM <br />JUL 23. 2010 <br />START TIME DISABLED <br />L13:13 <br />TRI—STATE (SINGLE FLOAT} <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />TEST RATE :0.20 GAL/HR <br />CATEGORY : OTHER SENSORS <br />ISD DEGRD PRES FAIL <br />DURATION : 2 HOURS <br />ISD VAPOR LEAK FAIL <br />TST EARLY STOP:DISABLED <br />ISD VP PRES FAIL <br />LEAK TEST REPORT FORMAT <br />L14:14 FLOAT} <br />TRI—STATE tSINGLE <br />ISD HOSE ALARMS <br />ALL:FLOW COLLECT FAIL <br />NORMAL <br />CATEGORY : OTHER SENSORS <br />