Laserfiche WebLink
T 2:UNLEADED REGULAR <br />PRODUCT CODE <br />2 <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />119.80 <br />TANK PROFILE <br />4 PTS <br />FULL VOL <br />15104 <br />89.9 INCH VOL <br />12340 <br />59.9 INCH VOL <br />7589 <br />30.0 INCH VOL <br />: 2843 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING : <br />2.0 <br />HIGH WATER LIMIT: <br />2.5 <br />MAX OR LABEL VOL: <br />15104 <br />OVERFILL LIMIT <br />90% <br />13593 <br />HIGH PRODUCT <br />95% <br />14348 <br />DELIVERY LIMIT <br />110% <br />10 <br />LOW PRODUCT 500 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />0.00 <br />TANK TILT <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />T#: NONE <br />LEAK MIN PERIODIC: oyo <br />PERIODIC TEST TYPE <br />STANDARD <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />PER TEST AVERAGING: OFF <br />I <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK, <br />JAN 29, 2009 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L 1:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 2:91 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGOR'. : ANNULAR SPACE <br />L 3:87 STP SUMP <br />TRI-STATELE <br />L 4:91 STP SUMP <br />CATEGORYE:(STP GFLOAT) <br />SUMP <br />L 5:DISP. 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />I <br />L 6:DISP. 3-4 !, <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 7:DISP. 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L B:DISP. 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 9:9 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L10:10 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L11:11 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L12:12 <br />CATEGORYE:(OTHERESENSORS I; <br />6 <br />w <br />L13:13 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L14:14 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L15:15 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />L16:16 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : OTHER SENSORS <br />OUTPUT RELAY SETUP <br />j R 1:87 RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 3:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />R 2:91 RELAY <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />L B:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />SMARTSENSOR SETUP <br />s 1:VENTS PSI <br />CATEGORY VAPOR PRESSURE <br />s 2:CCVP <br />CATEGORY VAPOR VALVE <br />s B:ATM P SENSOR <br />CATEGORY ATM P SENSOR <br />