Laserfiche WebLink
FA <br />CG <br />Well Proximity Proposal & <br />Cost Estimate <br />Scope of Work <br />Perform pretesting, vertical probe installation and on-site laboratory services required to perform Well Proximity Enhanced Leak Detection (ELD) testin( <br />services at the above referenced location. Owner to provide qualified fuel system repair contractor on stand by during on site testing activities at owner: <br />sole expense. It is required to have a stand-by contractor for the day of testing. In addition, this estimate is based on our understanding of the fueling <br />system, which is as follows: <br />1. Tanks - (1) 15k and (1) 10k both double wall FRP USTs <br />2. Sumps - (2) containing upper tank fittings and components <br />3. Under Dispenser Containment (UDC) - (4) <br />4. Vent and other Transition Sumps - (?) <br />5. Piping - (2) Product lines (DW FRP), (2) vent (DW FRP) and (1) vapor rec (DW FRP) <br />Costs for the testing assume that all site work can be completed within 16 hours on site. If the work takes longer than the specified time due to no fault <br />of CGRS, additional hourly fees will be incurred on a time and materials basis in accordance with our current fee schedule. <br />Leak Detection Services Initials <br />Item No. <br />Description <br />CGRS Contact: <br />Chris Murphy 916-991-1100 <br />Date: <br />September 9, 2011 <br />Customer Name: <br />cmurphy@cgrs.com <br />A -One Gas & Food <br />Facility: <br />76 Gas Station <br />Address: <br />574 West Grant Line Rd. <br />Address: <br />574 West Grant Line Rd. <br />City, State, Zip: <br />Tracy, CA 95376 <br />City, State, Zip: <br />Tracy, CA 95376 <br />Contact: <br />Ramesh Sood <br />County: <br />San Joaquin <br />Telephone/Email <br />209-833-3416/soodcoro0vahon rnm <br />Scope of Work <br />Perform pretesting, vertical probe installation and on-site laboratory services required to perform Well Proximity Enhanced Leak Detection (ELD) testin( <br />services at the above referenced location. Owner to provide qualified fuel system repair contractor on stand by during on site testing activities at owner: <br />sole expense. It is required to have a stand-by contractor for the day of testing. In addition, this estimate is based on our understanding of the fueling <br />system, which is as follows: <br />1. Tanks - (1) 15k and (1) 10k both double wall FRP USTs <br />2. Sumps - (2) containing upper tank fittings and components <br />3. Under Dispenser Containment (UDC) - (4) <br />4. Vent and other Transition Sumps - (?) <br />5. Piping - (2) Product lines (DW FRP), (2) vent (DW FRP) and (1) vapor rec (DW FRP) <br />Costs for the testing assume that all site work can be completed within 16 hours on site. If the work takes longer than the specified time due to no fault <br />of CGRS, additional hourly fees will be incurred on a time and materials basis in accordance with our current fee schedule. <br />Leak Detection Services Initials <br />Item No. <br />Description <br />Quantity <br />Unit <br />Price <br />1 <br />Onsite Tracer Tight® ELD Laboratory Services <br />Extended <br />2 <br />Mobilization & Perdiem <br />1 <br />flat rate <br />$ 5,500.00 <br />$ 5,500.00 <br />3 <br />Helium <br />1 <br />flat rate <br />$ 1,000.00 <br />$ 1,000.00 <br />4 <br />Permitting Fee (Cost + 10%) <br />1 <br />cylinder <br />$ 175.00 <br />$ 175.00 <br />5 <br />Estimated Sales Tax on Taxable Materials <br />1 <br />flat rate <br />$ 137.50 <br />$ 137.50 <br />6 <br />Additional hours beyond 16 hours of site work <br />1 <br />1 <br />lump sum <br />$ 17 06 <br />$ 17.06 <br />7 <br />Perdiem per man beyond two nights <br />hours <br />$ 305.06 <br />$ <br />0 <br />days <br />$ 150.00 <br />$ - <br />Printed Name Title ��- <br />