My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
574
>
2300 - Underground Storage Tank Program
>
PR0231405
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/13/2024 2:58:31 PM
Creation date
10/30/2018 1:37:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231405
PE
2361
FACILITY_ID
FA0003164
FACILITY_NAME
NORTH POLE GAS & FOOD INC
STREET_NUMBER
574
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
574 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L10:10 <br /> LEAK TEST METHOD TRI-STATE (SINGLE FLOAT) <br /> - - - - - - CATEGORY OTHER SENSORS <br /> TEST ON DATE : ALI. TANK <br /> JUL 23, 2010 <br /> START TIME : DISABLED <br /> TEST RATE :0.20 GALZHR_ L11 :11 " <br /> DURATION '2 HOURS TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : OTHER SENSORS <br /> T 2:87 TST El'RLY STOP:DISABLED <br /> PRODUCT CODE 2 <br /> THERMAL C•OEFF : .000700 LEAK TEST REPORT FORMAT <br /> TANK DIAMETER 119.80 NORMAL L12:12 <br /> TANK PROFILE 4 PBS TRI-STATE (SINGLE FLOAT) <br /> FULL VOL 15104 CATEGORY : OTHER SENSORS <br /> 89.9 INCH VOL : 12340 <br /> 59.9 INCH VOL 7589 <br /> 30.0 INCH VOL 2843 <br /> L13:13 <br /> TRI-STATE (SINGLE FLOAT) <br /> FLOAT SIZE: 4.0 IN. CATEGORY : OTHER SENSORS <br /> WATER WARNING 2,0 <br /> HIGH WATER LIMIT: 2.5 <br /> LIQUID SENSOR SETUP L14:14 <br /> MAX OR LABEL VOL: 15104 - - - - - - - - - TRI-STATE (SINGLE FLOAT) <br /> OVERFILL LIMIT 90% CATEGORY : OTHER SENSORS <br /> 13593 L 1 :87 ANNULAR <br /> HIGH PRODUCT 95%t, TRI-STATE (SINGLE FLOAT) <br /> 14348 CATEGORY : ANNULAR SPACE <br /> DELIVERY LIMIT 10% L15:15 <br /> 1510 TRI-STATE (SINGLE FLOAT) <br /> LOWPRODUCT 500 L 2:91 ANNULAR CATEGORY OTHER SENSORS <br /> LEAK ALARM LIMIT: 99 TRI-STATE (SINGLE FLOAT) <br /> SUDDEN LOSS LIMIT: 99 CATEGORY : ANNULAR SPACE <br /> TANK. TILT 0.00 1-16:16 <br /> PROBE OFFSET 0.00 TRI-STATE (SINGLE FLOAT) <br /> L 3:87 STP SUMPCATEGORY OTHER SENSORS <br /> SIPHON MANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) <br /> T#: NONE CATEGORY : STP SUMP ` <br /> LINE MANIFOLDED TANKS <br /> T#: NONE <br /> L 4:91 STP SUMP <br /> TRI-STATE (SINGLE FLOAT) <br /> LEAK MIN PERIODIC: 0%, CATEGORY : STP SUMP <br /> 0 <br /> PERIODIC TEST TYPE <br /> STANDARD L 5:D I SF' 1-2 <br /> TRI-STATE (SINGLE FLOAT) <br /> PERIODIC- TEST FAIL CATEGORY : DISPENSER PAN <br /> ALARM DISABLED OUTPUT RELAY SETUP <br /> GROSS TEST FAIL <br /> ALARM DISABLED L 6:DISP 3-4 R 1 :87 RELAY <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> PER TEST AVERAGING: OFF CATEGORY :. DISPENSER PAN STANDARD <br /> TANK TEST NOTIF'!: OFF NORMALLY CLOSED <br /> TNK TST SIPHON BREAK:OFF L 7:DISP 5-6 TANK #: 2 <br /> TRT-STATE (SINGLE FLOAT) <br /> DELIVERY DELAY 5 MIN CATEGORY : DISPENSER PAN LIQUID SENSOR ALM; <br /> PUMP THRESHOLD 10.00p L 3:FUEL ALARM <br /> L 5:FUEL ALARM <br /> L 6:FUEL ALARM <br /> L 8:DISP 7-8 L 7:FUEL ALARM <br /> TRI-STATE (SINGLE FLOAT) L 8:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L 3:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM <br /> L 6:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> L 9:9 L 8:SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) L 3:SHORT ALARM <br /> CATEGORY : OTHER SENSORS L 5:SHORT ALARM <br /> L 6:SHORT ALARM <br /> L 7:SHORT ALARM <br /> L 8:SHORT ALARM <br />
The URL can be used to link to this page
Your browser does not support the video tag.