Laserfiche WebLink
M �A T E R I A L S A F E T Y D A T A S H E E T POLYTREAT B-380-S <br /> BURMAH TECHNICAL SERVICES, INC. , Pontiac, MI 48058 Phone: 313-334-4747 <br /> Formerly Water Management Div. , Clow Corp. <br /> ----------------------------------------------------------------------------------------------- <br /> SECTION A - GENERAL INFORMATION <br /> ----------------------------------------------------------------------------------------------- <br /> CHEMICAL FAMILY n/a NAME POLYTREAT B-380-S <br /> FORMULA NA (Mixture) USE Boiler Water Treatment <br /> DOT HAZARD CLASS Corrosive material (liquid) UN/NA No. NA 1719 <br /> PROPER DOT NAME Alkaline liquid,n.o.s. <br /> ----------------------------------------------------------------------------------------------- <br /> SECTION B - HEALTH HAZARD INFORMATION <br /> ----------------------------------------------------------------------------------------------- <br /> ACUTE EXPOSURE EFFECTS <br /> EYES: Will produce severe irritation and possible chemical burns <br /> SKIN: Causes chemical burns <br /> INHALATION: May irritate respiratory tract <br /> INGESTION: Harmful if swallowed <br /> NOTES: None <br /> FIRST AID INFORMATION <br /> In case of contact, immediately flush eyes and skin with large quantities of <br /> water for at least 15 minutes while removing contaminated clothing and shoes. <br /> Call a physician. Wash clothing before reuse. Discard contaminated shoes. <br /> ----------------------------------------------------------------------------------------------- <br /> SECTION C - PERSONAL PROTECTION INFORMATION <br /> ----------------------------------------------------------------------------------------------- <br /> Eyes Face shield or chemical splash goggles. <br /> Skin/Gloves Rubber gloves <br /> Respiratory NIOSH approved respirator if local exposure limits may be exceeded. <br /> Ventilation Not normally required. <br /> Other None <br /> ----------------------------------------------------------------------------------------------- <br /> SECTION D - FIRE AND EXPLOSION HAZARDS <br /> ----------------------------------------------------------------------------------------------- <br /> Flash Point, IF None Flammability Limits NA <br /> ----------------------------------------------------------------------------------------------- <br /> EXTINGUISHING METHODS <br /> If involved in a fire, any suitable for cause of fire. <br /> -------------------------------------- M S D S ------------------------ Page 1 of 4 - <br /> NA=Not Applicable n/a=Not Available <br />