Laserfiche WebLink
San ,' tlin County Environmental Health ' artment <br /> Continued HAZARDOUbWASTE GENERATOR PROGRAM INSPEL-nift REPORT <br /> Facility Address: I f r r ��Gf-r1 Ins ti <br /> Code Section VIOIA71ONS <br /> 50 25160(d)HSC Transported hazardous waste without a manifest. <br /> Z 51 25163(a)HSC Transported hazardous waste or transferred HW to a transporter without valid registration. <br /> 52 <br /> 251160.21[c)(2)HSC Offered ineligible waste streams to be transported using consolidated manifest. <br /> 53 25160.2 b 4 HSC Consolidated manifest receipts failed to contain complete information. <br /> 54 25250.23 HSC Transported used oil and not registered as a hazardous waste hauler. <br /> 55 66263.17(a)CCR Transported hazardous waste without receiving ID Number and registration cert from DTSC. <br /> 56 66263.23(b)CCR Delivered hazardous waste to an unauthorized facility. <br /> 57 66265.17 CCR Failed to manage incompatible waste in containers properly. <br /> 58 66265.199 CCR Failed to manage incompatible waste in tanks properly. <br /> 59 25250.7 HSC Contaminated used oil with other hazardous waste. <br /> 60 1 66266.81 b CCR Damaged lead acid batteries not properly managed and labeled. <br /> 61 66265.191 a CCR Failed to determine if HW tank is leaking or unfit. <br /> 62 66265.191(b)CCR HW tank assessment not sufficient. <br /> Y 63 66265.191(d)CCR If HW tank found leaking or unfit,failed to comply with 66265.196. <br /> 64 66265.192 CCR Failed to retain on-site required certification for HW tanks. <br /> 65 66265.193 CCR Failed to provide secondary containment for HW tank. <br /> 66 66265.194(a)CCR Placed hazardous waste or reagents in tank system that caused the tank,containment <br /> system or ancillary equipment to leak,corrode,rupture,or fail. <br /> 3 67 66265.194(b)CCR Failed to use controls and practices to prevent spillage and overflows from tank system. <br /> rn 68 66265.194 b 3 CCR Failed to prevent overtopping from HW tank. <br /> 7 <br /> 0 69 66265.195(a)CCR Failed to conduct daily inspections of HW tank. <br /> 70 66265.195(b)CCR Failed to inspect HW tank cathodic protections stem. <br /> 71 66265.196 CCR Failed to immediately remove tank/secondary containment system that had leaked or spilled. <br /> x 72 66265.197 CCR Tank closure,failed to remove/decon all waste and manage them as HW. <br /> 73 66265.19 ay b CCR Failed to manage ignitable or reactive waste properly. <br /> 74 66265.19 a b CCR Failed to manage incompatible wastes properly. <br /> 75 66273.32(a)CCR Failed to notify the EPA RA to obtain an EPA ID#prior to accumulating>5000k of UW. <br /> 76 66273.32(c)CCR Cathode Ray Tube CRT handler failed to notify DTSC 30 days prior to accepting offsite UW. <br /> 77 66273.33(a)CCR Failed to store UW batteries in a closed container and in a manner that prevents breakage <br /> and release to the environment. <br /> Failed to:(1)store UW lamps in a closed container and in a manner that prevents breakage <br /> 78 66273.33(b)CCR and release to the environment,or(2)immediately clean and containerize any broken lamps <br /> or releases to the environment. <br /> LU <br /> Failed to store mercury containing UW in closed or airtight containers in a manner that <br /> a 79 66273.33(c)CCR prevents breakage and release to the environment,or failed to immediately clean and <br /> containerize any broken mercury containing UW or release to the environment. <br /> Failed to:(1)store a UW electronic device in a manner that prevents breakage and release to <br /> K 80 66273.33.5(aX1 XB)CCR the environment,or(2)immediately clean and containerize any broken electronic device or <br /> release to the environment. <br /> Failed to:(1)contain a CRT in a manner that prevents breakage and release to the <br /> 81 66273.33.5(b)(iXB)CCR environment,or(2)immediately clean and containerize any broken CRT or release to the <br /> environment. <br /> 82 66273.34 CCR Failed to label universal waste to identify type of universal waste. (a)Batteries,(b)Mercury <br /> containingequipment, c Lamps, d Electronic devices, a CRTs, CRT lass <br /> 83 66273.35 CCR (a)Stored UW onsite for more than 1 year,or(b)was unable to demonstrate the length of <br /> time the UW has been accumulated from the date it became a waste or was received. <br /> 84 66273.36 CCR Training records for UW management and emergency response procedures incomplete. <br /> 85 66273.39 CCR Failed to keep records of each shipment of universal waste according to this section. <br /> 66262.34(d)CCR 8 <br /> 86 Stored hazardous waste onsite greater than 180 days. <br /> 25123. h 1 HSC <br /> 87 66262. d 1 CCR Accumulated more than 6,000 kg of HW onsite at one time. <br /> s 88 66262.34(dX2)CCR Modified emergency coordinator information lacking or insufficient(as referenced by CFR <br /> 262.34(d)and CFR e <br /> 89 66261.7(f)CCR An empty HW or Haz Mat container(larger than 5 gallons)was not marked with the date it <br /> was em tied/not managed within one year of beingemptied. <br /> 0 90 25217.1 HSC Li uid latex aint was disposed of or attempted to be disposed of,to land or water. <br /> 91 1 1 1 See attached*Continuation-Official Inspection Report'for violations not listed above. <br /> UIC I Septic System:_Serves>20 persons/day _Receives other than sanit ry w e _Dry wells/French Drains Onsite <br /> END Inspector. Receiv Ti <br /> of "2 <br /> END 22-02-004 Rev 3/09 600 EAST MAIN STREET,STOCKTON,CA 95202(209)468-3420 Page 2 <br />