My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4800
>
2200 - Hazardous Waste Program
>
PR0513729
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2024 4:51:35 PM
Creation date
10/31/2018 8:59:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513729
PE
2220
FACILITY_ID
FA0003809
FACILITY_NAME
A G SPANOS AVIATION DEPT*
STREET_NUMBER
4800
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
4800 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\4800\PR0513729\COMPLAINCE INFO 2017 - PRESENT .PDF
QuestysFileName
COMPLAINCE INFO 2017 - PRESENT
QuestysRecordDate
10/3/2017 9:06:47 PM
QuestysRecordID
3661269
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.or0/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A G SPANOS AVIATION DEPT` 4800 S AIRPORT WAY, STOCKTON February 23,2018 <br /> Treatment,Transport and Disposal <br /> 208 HSC 25200.3.1(c) Failure of laboratory to comply with hazardous waste treatment requirements o V o R o COS <br /> 209 CCR 66262.34(4)(2) Failure to remove all hazardous waste from tanks,containers and containment upon facility closure o V o R o COS <br /> Preparedness and Prevention <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste C V o R o COS <br /> 302 CCR 66262.34(4)(2) Failed to maintain required emergency equipment in V o R in COS <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems,spill control,or decontamination equipment in V o R o COS <br /> 304 CCR 66262.34(4)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies o V o R o COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition o V o R o COS <br /> 402 CCR 66262.34(d)(2) Failed to store hazardous waste in a compatible container o V C R o COS <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste o V o R o COS <br /> 404 CCR 66262.34(4)(2) Failed to inspect hazardous waste storage areas at least weekly o V o R o COS <br /> 405 CCR 66262.34(d)(2) Failed to manage incompatible wastes in containers properly o V o R o COS <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied o V o R o COS <br /> 407 CCR 66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator o V o R o COS <br /> 408 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely FW)per waste stream c V u R -COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank n V o R o COS <br /> 502 CCR 66262.34(d)(2) Tank system inspections of discharge systems,monitoring equipment,and tank levels not done daily o V o R o COS <br /> 503 CCR 66262.34(d)(2) Tank system inspections of construction materials,fixtures,and surrounding areas not done weekly o V o R o COS <br /> 504 CCR 66262.34(4)(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment u V o R o COS <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks o V R o COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days u V o R o COS <br /> 602 CCR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longer than one year or 180 days after fill date o V o R o COS <br /> 603 CCR 66262.34(e)(1)(C) Failed to mark initial accumulation start date on satellite containers o V in R o COS <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days u V u R o COS <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste o V o R o COS <br /> 606 CCR 66266.81(a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V in R o COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not properly managed and labeled o V o R o COS <br /> 608 CCR 66266.130 Failed to property manage used oil and fuel fitters o V o R o COS <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials o V o R o COS <br /> 610 CCR 66262.34(b)(1) Stored acutely or extremely hazardous waste onsite greater than 90 days in V in R o COS <br /> 611 HSC 25200.3.1(b) Failure of laboratory to comply with hazardous waste accumulation area requirements o V o R u COS <br /> Universal Waste <br /> FA0003809 PRO513729 SCO01 0223/2018 <br /> EHD 22-01 Rev.0922/16 Page 2 of 5 Small Quantity Hazardous waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.