...01 <br /> Emergency Response/Contingency Plan(HMBP Module) Page 2 of 5 <br /> Emergency Procedures: <br /> rgencv Coordinator Responsibilities: <br /> a. Whenever there is an imminent or actual emergency situation such as a explosion, fire, or release,the emergency coordinator(or <br /> his/her designee when the emergency coordinator is on call)shall: <br /> i. Identify the character,exact source,amount,and areal extent of any released hazardous materials. <br /> ii. Assess possible hazards to human health or the environment that may result from the explosion, fire, or release. This <br /> assessment must consider both direct and indirect effects (e.g. the effects of any toxic, irritating, or asphyxiating gases that <br /> are generated, the effects ofany hazardous surface water run-ojffrom water or chemical agents used to control fire, etc). <br /> iii. Activate internal facility alarms or communications systems,where applicable,to notify all facility personnel. <br /> iv. Notify appropriate local authorities(i.e. call 911). <br /> v. Notify the State Office of Emergency Services at 1-800-852-7550. <br /> vi. Monitor for leaks,pressure build-up,gas generation,or raptures in valves,pipes,or other equipment shut down in response to <br /> the incident. <br /> vii. Take all reasonable measures necessary to ensure that fires, explosions, and releases do not occur, recur, or spread to other <br /> hazardous materials at the facility. <br /> b. Before facility operations are resumed in areas of the facility affected by the incident,the emergency coordinator shall: <br /> i. Provide for proper storage and disposal of recovered waste, contaminated soil or surface water, or any other material that <br /> results from a explosion,fire,or release at the facility. <br /> ii. Ensure that no material that is incompatible with the released material is transferred, stored, or disposed of in areas of the <br /> facility affected by the incident until cleanup procedures are completed. <br /> 1 iii. Ensure that all emergency equipment is cleaned,fit for its intended use, and available for use. <br /> iv. Notify the California Environmental Protection Agency's Department of Toxic Substances Control, and the local fire <br /> department's hazardous materials program that the facility is in compliance with requirements b-i and b-ii,above. <br /> Responsibilities of Other Personnel: <br /> On a separate page, list any emergency response functions not covered in the "Emergency Coordinator Responsibilities" section, <br /> above. Next to each function, list the job title or name of each person responsible for performing the function. Number the page(s) <br /> appropriately. <br /> 15. Post-Incident Reporting/Recording: <br /> The time,date,and details of any hazardous materials incident that requires implementation of this plan shall be noted in the facility's <br /> 'operating record. <br /> Within 15 days of any hazardous materials emergency incident or threatened hazardous materials emergency incident that triggers <br /> implementation of this plan, a written Emergency Incident Report, including,but not limited to a description of the incident and the <br /> facility's response to the incident, must be submitted to the California Environmental Protection Agency's Department of Toxic <br /> Substances Control and the local fire department's hazardous materials program. The report must include: <br /> a. Name,address,and telephone number of the facility's owner/operator; <br /> b. Name,address,and telephone number of the facility; <br /> C. Date,time,and type of incident(e.g.fire, explosion, etc); <br /> d. Name and quantity of material(s)involved; <br /> e. The extent of injuries,if any; <br /> f. An assessment of actual or potential hazards to human health or the environment,where this is applicable; <br /> g. Estimated quantity and disposition of recovered material that resulted from the incident; <br /> h. Cause(es)of the incident; <br /> 1 i. Actions taken in response to the incident; <br /> ? j. Administrative or engineering controls designed to prevent such incidents in the future. <br /> I <br /> Based on UN-020-11/17 Rev.04/30/01 <br />