Hazardous Waste Management <br /> TRAINING HANDOUT <br /> Resource Conservation and Recovery Act Listed Waste <br /> (RCRA) Employee training requirements ■ Harmful to Human Health and the Environment <br /> ■ Hazardous Waste Management Procedures ■ The lists include: <br /> ■ Emergency Response 1. Non-Specific Source Wastes(F-listed) <br /> ■ Hazard Communication 2. Specific Source Wastes(K-listed) <br /> 3. Discarded Commercial Chemical Products(P <br /> Training Outline &U-listed) <br /> ■ Hazardous Waste Generator Status <br /> ■ Waste Determination Container Management <br /> ■ Container Management ■ Containers must be in good condition and <br /> ■ Accumulation Time and Storage Limits compatiblewith the materials stored within <br /> ■ Labeling ■ Containers must remain closed at all times except to <br /> ■ Recordkeeping add or remove waste <br /> ■ Weekly Inspections <br /> Determining Generator Status ■ Do not mix incompatible wastes <br /> ■ Conditionally Exempt Small Quantity Generators ■ Containers of incompatible wastes should be <br /> (CESQGs) separated <br /> ■ Small Quantity Generators(SQGs) ■ Containers must be handled in a manner that prevents <br /> ■ Large Quantity Generators(LQGs) leaks <br /> Basic Requirements for Small Quantity Weekly Inspection Log <br /> Generators ■ Signed and dated weekly <br /> ■ Number of containers and general condition <br /> ■ Waste Determination <br /> 1. Generator Knowledge ■ General observations and remedial actions <br /> 2. Testing Representative Sample ■ Hazardous Waste label completion <br /> ■ Hazardous Wastes Defined by EPA ■ Maintain aisle space between containers <br /> 1. Characteristic <br /> 2. Listed Proper Storage <br /> ■ Do not overfill <br /> Characteristic Wastes ■ Maintain three inches of air space <br /> ■ Spill response equipment on hand <br /> ■ Ignitable <br /> ■ Corrosive ■ Keep containers closed <br /> ■ Reactive <br /> ■ Toxic Accumulation Time and Storage Limits <br /> ■ CESQGs:indefinitely if<220 lbs/month or a total< <br /> Ignitable Waste 2200 lbs onsite. <br /> ■ Flash point of less than 140°Fahrenheit. ■ SQGs: 180 days if<2200 lbs/month or a total<6600 <br /> ■ Waste code"D001" lbs onsite. <br /> ■ 90-day extension <br /> Corrosive Waste Labeling <br /> ■ pH less than or equal to 2 or greater than or equal to <br /> 12.5 ■ Generator Contact Info■ Waste code"13002" ■ EPA ID Number <br /> ■ Manifest Number <br /> ■ Accumulation Start Date <br /> Reactive Waste ■ EPA Waste Numbers <br /> ■ Unstable under"normal"conditions ■ DOT Shipping Name <br /> ■ Waste Code"D003 <br /> Toxic Waste Recordkeeping and Reporting <br /> ■ Generator and TSDF Manifest copies <br /> ■ Harmful or fatal when ingested or absorbed ■ Land Disposal Restriction Form <br /> ■ Defined through TCLP testing ■ Keep all records in the Yellow Box <br /> ■ Waste codes"D004"through"D043" ■ Three year record retention <br /> IfPA <br />