Laserfiche WebLink
SANJ O A Q U I I Environmental Health Department <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SGS Stockton -Carpenter Road 4863 CARPENTER RD, Stockton February 26, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> The eye wash station located inside the mechanic shop didn't not appear to be inspected/maintained as required, <br /> the bottle eye wash solution had an expiration date of March 2015 and the stationary (wall mounted) eye wash <br /> station had an inspection log with inspection dates in the future(on 2-29-2016- in the future from today's <br /> inspection). All facility communications or alarm systems, fire protection equipment, spill control equipment, and <br /> decontamination equipment, where required, shall be tested and maintained as necessary to assure its proper <br /> operation in time of emergency. Immediately begin this practice. <br /> This is a Class II violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> One oil drain pan container located inside the mechanic shop was at least 1/2 full containing dark oily liquid, the <br /> facility representative indicated that they empty the drain pan periodically "could be a week or could be couple of <br /> weeks."All hazardous waste containers shall be closed at all times except when adding or removing waste. <br /> Immediately close these containers and ensure all hazardous waste containers are closed when not adding or <br /> removing waste. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or tanks of hazardous waste. <br /> The following containers were noted at the time of inspection: <br /> 1) One oil drain container located inside the mechanic shop was at least 1/2 full containing dark oily liquid, the <br /> facility representative indicated that they empty the drain pan periodically"could be a week or could be couple of <br /> weeks." <br /> 2) One 30 gallon container or("Arma Clean") located inside the mechanic shop lacked hazardous properties and <br /> physical state on its label. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words "Hazardous Waste" <br /> - name and address of generator <br /> - hazardous properties <br /> - physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Onsite to conduct a routine hazardous waste generator inspection. At the time of inspection, the San Joaquin <br /> County Environmental Health Department (EHD) inspectors (Stacy Rivera and Elena Manzo) were accompanied <br /> by several SGS Stockton facility representatives (Mr. John Pallen, Mr. Danie Perez, and Mr. Stevan Dearrillaga <br /> Jr). <br /> FA0005712 PR0539280 SCO01 02/26/2016 <br /> EHD 22-01 Rev.09/27/2018 Page 5 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />