My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
4863
>
2200 - Hazardous Waste Program
>
PR0539280
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/8/2020 2:47:21 PM
Creation date
10/31/2018 11:45:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0539280
PE
2220
FACILITY_ID
FA0005712
FACILITY_NAME
SGS Stockton - Carpenter Road
STREET_NUMBER
4863
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
17905010
CURRENT_STATUS
01
SITE_LOCATION
4863 CARPENTER RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\C\CARPENTER\4863\PR0539280\COMPLIANCE INFO\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
3/2/2016 6:36:56 PM
QuestysRecordID
2029384
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County iti� <br /> Environmental Health Department AMN M <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 — fo <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SGS Stockton - Carpenter Road 4863 CARPENTER RD Stockton February 26 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> The eye wash station located inside the mechanic shop didn't not appear to be inspected/maintained as required, the <br /> bottle eye wash solution had an expiration date of March 2015 and the stationary (wall mounted) eye wash station had <br /> an inspection log with inspection dates in the future(on 2-29-2016- in the future from today's inspection). All facility <br /> communications or alarm systems, fire protection equipment, spill control equipment, and decontamination <br /> equipment, where required, shall be tested and maintained as necessary to assure its proper operation in time of <br /> emergency. Immediately begin this practice. <br /> This is a Class II violation. <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> One oil drain pan container located inside the mechanic shop was at least 1/2 full containing dark oily liquid, the <br /> facility representative indicated that they empty the drain pan periodically"could be a week or could be couple of <br /> weeks."All hazardous waste containers shall be closed at all times except when adding or removing waste. <br /> Immediately close these containers and ensure all hazardous waste containers are closed when not adding or <br /> removing waste. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or tanks of hazardous waste. <br /> The following containers were noted at the time of inspection: <br /> 1) One oil drain container located inside the mechanic shop was at least 1/2 full containing dark oily liquid, the facility <br /> representative indicated that they empty the drain pan periodically"could be a week or could be couple of weeks." <br /> 2) One 30 gallon container or ("Arma Clean") located inside the mechanic shop lacked hazardous properties and <br /> physical state on its label. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> - name and address of generator <br /> - hazardous properties <br /> - physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Onsite to conduct a routine hazardous waste generator inspection. At the time of inspection, the San Joaquin <br /> County Environmental Health Department (EHD) inspectors (Stacy Rivera and Elena Manzo) were accompanied <br /> by several SGS Stockton facility representatives (Mr. John Pallen, Mr. Danie Perez, and Mr. Stevan Dearrillaga <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.