My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1501
>
2200 - Hazardous Waste Program
>
PR0540911
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 10:43:33 AM
Creation date
10/31/2018 11:58:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0540911
PE
2220
FACILITY_ID
FA0015913
FACILITY_NAME
Garcha Tires & Repair
STREET_NUMBER
1501
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
Way
City
Stockton
Zip
95206
CURRENT_STATUS
01
SITE_LOCATION
1501 W Charter Way
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1501\PR0540911\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
9/15/2016 3:31:46 PM
QuestysRecordID
3190897
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GARCHA TIRES & REPAIR 1501 W CHARTER WAY. STOCKTON August 11, 2016 <br /> Preparedness and Prevention <br /> 307 CCR 66262.34(d)(2) I Facility not maintained to minimize the release of a hazardous waste .V _ R -COS <br /> 302 CCR 66262.34(d)(2) Failed to maintain required emergency equipment D V o R D COS <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems,spill control,or decontamination equipment D V o R o COS <br /> 304 CCR 66262.34(d)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies o V o R D COS <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition o V o R o COS <br /> 402 CCR 66262.34(d)(2) Failed to store hazardous waste in a compatible container o V o R o COS <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste .V o R o COS <br /> 404 CCR 66262.34(d)(2) Failed to inspect hazardous waste storage areas at least weekly o V o R o COS <br /> 405 CCR 66262.34(4)(2) Failed to manage incompatible wastes in containers property o V o R o COS <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied o V o R c COS <br /> 407 CCR 66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator o V u R o COS <br /> 408 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste stream n V e R o COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank D V o R o COS <br /> 502 CCR 66262.34(d)(2) Tank system inspections of discharge systems,monitoring equipment,and tank levels not done daily o V o R o COS <br /> 503 CCR 66262.34(d)(2) Tank system inspections of construction materials,fixtures,and surrounding areas not done weekly u V o R o COS <br /> 504 CCR 66262.34(d)(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment o V D R o COS <br /> 505 CCR 66262.34M Failed to completely label stationary hazardous waste tanks o V o R o COS <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days ■V o R o COS <br /> d <br /> CR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longer than one year or 180 days after fill date o V u R o COS <br /> CR 66262.34(e)(1)(C) Failed to mark initial accumulation start date on satellite containers o V o R u COS <br /> CR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days o V o R o COS <br /> CR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste ■V o R o COS <br /> 606 CCR 66266.81(a)(3) I Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V o R n COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not property managed and labeled o V o R u COS <br /> 608 CCR 66266.130 Failed to property manage used oil and fuel filters ■V o R o COS <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials o V u R o COS <br /> 701 CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID#prior to accumulating>5000kg of UW o V c R o COS <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW o V o R o COS <br /> 703 CCR 66273.33(a) Failed to store UW batteries in a manner that prevents breakage and release to the environment o V u R o COS <br /> 704 CCR 66273.33(b) Failed to property manage universal waste lamps o V c R D COS <br /> Page 2 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.