Laserfiche WebLink
Ch. 15,Art. 10-2 <br /> pursuant to HSC 25200.3,and Conditional Exemption pursuant to HSC 25201.5,and <br /> (B)onground or aboveground tank systems containing RCRA hazardous wastes generated onsite, if: <br /> 1.the owner or operator is a conditionally exempt small quantity generator as defined in 40 CFR section <br /> 261.5,or a small quantity generator of more than 100 kg but less than 1000 kg per month as defined in 40 CFR <br /> section 265.201,or <br /> 2.the owner or operator is not subject to regulation in 40 CFR part 265 pursuant to an exemption in 40 CFR <br /> section 265.1, but the owner or operator is subject to the standards of this article. <br /> (f)A generator or owner or operator authorized pursuant to Permit-by-Rule pursuant to Chapter 45 of this <br /> division,Conditional Authorization pursuant to HSC 25200.3,or Conditional Exemption pursuant to HSC 25201.5, <br /> operating a non-RCRA underground tank system or an underground tank system otherwise exempt from permitting <br /> requirements pursuant to the federal act,shall comply with the applicable standards of Title 23 of the California Code <br /> of Regulations relating to underground tank systems. <br /> (g)The tank system assessment shall include all of the following information: <br /> (1)tank configuration(i.e., horizontal,vertical),and gross capacity(in gallons); <br /> (2)design standard(s),if available,according to which the tank and ancillary equipment we11e ruJ6d1 q" ;'F" 'c <br /> and all of the following information; <br /> ] y fr ,_- <br /> (A)material of construction; Pi <br /> (B)material thickness and the method used to determine the thickness; <br /> (C)description of tank system piping(material,diameter); DEC U 8 2016 <br /> (D)description of any internal and external pumps;and <br /> (E)sketch or drawing of tank including dimensions. <br /> (3)documented age of the tank system, if available,otherwise,an estimate of the age basecNIWP4 NMENTAL HEALP <br /> operator knowledge; <br /> (4)description and evaluation of the adequacy of any leak detection equipment; DERPATi`V'iEEN T <br /> (5)description and evaluation of any corrosion protection equipment; <br /> (6)description and evaluation of any spill prevention or overfill equipment; <br /> (7)hazardous characteristics of the waste(s)that have been or will be handled; <br /> (8)description of any structural damage or inadequate construction or installation such as cracks, punctures, <br /> or damaged fittings. All discrepancies shall be documented in the assessment and remedied before the tank system <br /> is certified for use. <br /> (9)results of a leak test, internal inspection,or other tank system integrity examination including the type of <br /> integrity examination performed(i.e., ultrasonic,internal examination,volumetric tank test,pipeline pressure test). <br /> Tank system integrity or leak test requirements must be in compliance with all local requirements. Prior to conducting <br /> a tank system integrity test or leak test,contact local agency staff for local requirements. <br /> (10)estimated remaining service life of the tank system based on findings of subsections(g)(1)through <br /> NOTE:Authority cited:Sections 25150,25159,and 58012, Health and Safety Code, Reference:Sections 25159 and <br /> 25159.5, Health and Safety Code;40 CFR Section 265.191. <br /> HISTORY <br /> 1. New section fled 5-24-91;operative 7-1-91 (Register 91,No.22). <br /> 2.Amendment filed 6-19-95 as an emergency;operative 6-19-95(Register 95, No.25).A Certificate of Compliance <br /> must be transmitted to CAL by 10-17-95 or emergency language will be repealed by operation of law on the following <br /> day. <br /> 3.Amendment refiled 10-16-95 as an emergency;operative 10-16-95(Register 95, No.42).A Certificate of <br /> Compliance must be transmitted to CAL by 2-13-96 or emergency language will be repealed by operation of law on <br /> the following day. <br /> 4.Amendment refiled 2-16-96 as an emergency;operative 2-16-96(Register 96,No.7).A Certificate of Compliance <br /> must be transmitted to OAL by 6-15-96 or emergency language will be repealed by operation of law on the following <br /> day. <br /> 5.Amendment refiled 6-17-96 as an emergency;operative 6-17-96(Register 96, No.25).A Certificate of Compliance <br /> must be transmitted to CAL by 10-15-96 or emergency language will be repealed by operation of law on the following <br /> day. <br /> 6.Amendment refiled 10-15-96 as an emergency;operative 10-15-96(Register 96,No.42).A Certificate of <br /> Compliance must be transmitted to CAL by 2-12-97 or emergency language will be repealed by operation of law on <br /> the day. <br /> 7.Amendment refiled 2-11-97 as an emergency, including amendment of NOTE;operative 2-11-97(Register 97, No. <br /> 7).A Certificate of Compliancefnust be transmitted to CAL by 6-11-97 or emergency language will be.repealed by <br /> operation of law on the following day. <br /> 8. Certificate of Compliance as to 2-11-97 order transmitted to CAL 6-10-97;disapproved by CAL and order of repeal <br /> as to 2-11-97 filed on 7-24-97(Register 97, No. 30). <br /> 9.Certificate of Compliance as to 2-11-97 order, including amendment of section and NOTE, resubmitted to CAL and <br /> approved on 7-24-97(Register 97, No.30). <br /> 10.Change without regulatory effect amending subsection(g)(3)filed 7-1-2004 pursuant to section 100,title 1, <br /> California Code of Regulations(Register 2004, No.27). <br /> 11.Amendment of subsection(a), repealer of subsections(a)(1)-(a)(2)(13)2.,amendment of subsection (c), repealer <br /> Unofficial Title 22©2005 State of California,all rights reserved.May not be commercially reproduced or sold. 6/9/08 <br />