My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLARK
>
3927
>
2200 - Hazardous Waste Program
>
PR0514138
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2019 4:22:31 PM
Creation date
10/31/2018 12:27:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514138
PE
2230
FACILITY_ID
FA0010034
FACILITY_NAME
PNP Stockton #80
STREET_NUMBER
3927
Direction
E
STREET_NAME
CLARK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17917109
CURRENT_STATUS
01
SITE_LOCATION
3927 E CLARK DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CLARK\3927\PR0514138\COMPLIANCE INFO 1991 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 1991 - 2011
QuestysRecordDate
11/14/2017 5:47:21 PM
QuestysRecordID
3727153
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1543
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
is <br /> I <br /> Data Qualifiers and Definitions (' <br /> Oealifiers Analyte was present in an associated method blank. Associated sample data was reported with i <br /> qualifier. <br /> Bi Analyte was present In an sample and associated method blank greater than MDL but less than j <br /> DRL. Associated sample data was reported with qualifier. <br /> Sol No valid test replicates.Result may be greater. Best result was reported with qualifier. Sample toxicity i <br /> possible. <br /> BQ2 No valid test replicates. <br /> BQ3 Minimum DO Is less than 1.0 mg/L. Result may be greater and reported with qualifier. <br /> C Laboratory Contamination. I <br /> D RPD was not within control limits,the sample data was reported without further clarification. <br /> D1 Lesser amount of sample was used due to insufficient amount of sample supplied <br /> DW Sample result is calculated on a dry weigh basis <br /> J Reported value is estimated j <br /> L The laboratory control sample(LCS)or laboratory control sample duplicate(LCSD)was out of control <br /> limits. Associated sample data was reported with qualifier. <br /> M The matrix spike(MS)or matrix spike duplicate(MSD)was not within control limits due to matrix <br /> interference.The associated LCS and/or LCSD was within control limits and the sample data was <br /> reported without further clarification. <br /> NC The analyte concentration in the sample exceeded the spike level by a factor of four or greater,spike i <br /> recovery and limits do not apply. <br /> P Sample was received without proper preservation according to EPA guidelines, <br /> P1 Temperature of refrigerator was out of acceptance limit due to technical difficulty. <br /> Q1 Analyte Calibration Verification exceeds criteria and the result was reported with qualifier. <br /> Q2 Analyte calibration was not verified and the result was estimated and reported with qualifier. <br /> Q3 Analyte initial calibration was not available or exceeds criteria.The result was estimated and reported <br /> with qualifier. <br /> Q4 Analyte result out of calibration range and was reported with qualifier <br /> 5 The surrogate recovery was out of control limits due to matrix interference.The associated method <br /> blank surrogate recovery was within control limits and the sample data was reported without further <br /> clarification. <br /> T Sample was extracted/analyzed past the holding time. <br /> T1 Reanalysis was reported past hold time due to failing replicates in the original analysis(BOD only). <br /> T2 Sample was analyzed ASAP but received and analyzed past the 15 minute holding time. <br /> T3 Sample received and analyzed out of hold time per client's request <br /> T4 Sample was analyzed out of hold time per client's request i <br /> T5 Reanalysis was reported past hold time. The original analysis was within hold time, but not <br /> reportable. <br /> T6 Hold time is indeterminable due to unspecified sampling time. <br /> Def!n itiQns <br /> OF Dilution Factor <br /> MDL Method Detection Limit. Result is reported ND when it is less than or equal to MDL. <br /> ND Analyte was not detected or was less than the detection limit. <br /> RDL Reporting Detection Limit , <br /> TIC Tentatively Identified Compounds <br /> ASSOCIATED LABORATORIES Analytical Results Report <br /> — <br /> 38334-01 <br /> Lab Request 955920,Page 3 of 3 .. <br />
The URL can be used to link to this page
Your browser does not support the video tag.