My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CLIFTON COURT
>
14333
>
2200 - Hazardous Waste Program
>
PR0538593
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2020 3:57:48 PM
Creation date
10/31/2018 12:38:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0538593
PE
2220
FACILITY_ID
FA0016950
FACILITY_NAME
FERGUSON RANCH LLC
STREET_NUMBER
14333
Direction
W
STREET_NAME
CLIFTON COURT
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
18925024
CURRENT_STATUS
02
SITE_LOCATION
14333 W CLIFTON COURT RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Supplemental fields
FilePath
\MIGRATIONS\C\CLIFTON COURT\14333\PR0538593\COMPLIANCE INFO 2017 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
5/3/2017 6:23:49 PM
QuestysRecordID
3374445
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.oro/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FERGUSON FARMS INC SITE 1 NORTH 1 14333 W CLIFTON CT RD STOCKTON Aril 26 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is not posted at the facility. There must be at <br /> least one emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone:the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment,and if present,fire alarm; and the phone number of the fire department, unless <br /> the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required information at the <br /> area where hazardous waste is being generated. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 105 CCR 66262.34(d)(2) No emergency coordinator. <br /> An emergency coordinator and modified contingency plan information is not posted at the facility. There must be at <br /> least one emergency coordinator on site or on call to coordinate emergency response measures,and the following <br /> information must be posted by a phone:the name and phone number of the emergency coordinator; location of fire <br /> extinguishers,spill control equipment, and if present,fire alarm; and the phone number of the fire department, unless <br /> the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required information at the <br /> area where hazardous waste is being generated. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 505 CCR 66262.34(f)Failed to completely label stationary hazardous waste tanks. <br /> The facility has a 500 gallon used oil tank in the"south"area. The tank is labeled"used oil'only. All hazardous <br /> waste tanks shall be marked with the words"Hazardous Waste"and the accumulation start date. Immediately ensure <br /> that all hazardous waste tanks are marked with the required information. <br /> This is a minor violation. <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> Facilities who generate less than 1000 kg of hazardous waste per month and do not exceed 6000 kg of waste stored <br /> on site at any time may store waste on site up to 180 days. The"south"used oil tank was missing an accumulation <br /> start date. Since it cannot be determined how long the hazardous waste has been on site, immediately contact a <br /> licensed hazardous waste hauler to dispose of this waste under manifest. Submit a copy of the manifest to the EHD <br /> within 30 days. <br /> This is a Class II violation. <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel filters. <br /> Oil filters were stored in open and unlabeled containers. Used oil filters shall be drained of free-flowing oil, stored in a <br /> closed, rainproof container, labeled as"drained used oil filters,"and marked with an accumulation start date. <br /> Immediately label and securely close the filter drums and ensure that all used oil filters are managed in this way. <br /> Properly dispose of the filters within one year of generation and keep the recycling records for three years. <br /> This is a minor violation. <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.