Laserfiche WebLink
Metals Fractional Narrative <br />Lawrence Livermore National Labs (LLNL) <br />SDG 197827 <br />Sample Analysis <br />Sample ID <br />197827001 <br />1201463116 <br />1201463117 <br />1201463120 <br />1201463118 <br />1201463119 <br />1201466359 <br />1201466360 <br />1201466363 <br />1201466361 <br />1201466362 <br />Client ID <br />83461 <br />Method Blank (MB) ICP <br />Laboratory Control Sample (LCS) <br />197821001(83462L) Serial Dilution (SD) <br />197821001(83462D) Sample Duplicate (DUP) <br />197821001(834625) Matrix Spike (MS) <br />Method Blank (MB) CVAA <br />Laboratory Control Sample (LCS) <br />197821001(83462L) Serial Dilution (SD) <br />197821001(83462D) Sample Duplicate (DUP) <br />197821001(83462S) Matrix Spike (MS) <br />The sample in this SDG was analyzed on an "as received" basis. <br />Method/Analysis Information <br />Analytical Batch: <br />703346 and 704867 <br />Prep Batch : <br />703345 and 704866 <br />Standard Operating <br />GL -MA -E-013 REV# 17, GL -MA -E-006 REV# 9 and GL - <br />Procedures: <br />MA -E-010 REV# 18 <br />Analytical Method: <br />SW846 3005/6010B and SW846 7470A <br />Prep Method : <br />SW846 3005A and SW846 7470A Prep <br />Preparation/Analytical Method Verification <br />The SOP stated above has been prepared based on technical research and testing <br />conducted by GEL Laboratories, LLC. and with guidance from the regulatory documents <br />listed in this "Method/Analysis Information" section. <br />System Confizuration <br />The Metals analysis -ICP was performed on a P E 4300 Optima radial/axial-viewing <br />inductively coupled plasma atomic emission spectrometer. The instrument is equipped <br />Page 12 of 36 <br />