My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DOUGLAS
>
1807
>
2200 - Hazardous Waste Program
>
PR0514131
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2024 2:16:07 PM
Creation date
10/31/2018 3:34:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0514131
PE
2221
FACILITY_ID
FA0003905
FACILITY_NAME
PAIGES TOWING
STREET_NUMBER
1807
STREET_NAME
DOUGLAS
STREET_TYPE
RD
City
STOCKTON
Zip
95207
APN
09721019
CURRENT_STATUS
02
SITE_LOCATION
1807 DOUGLAS RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\D\DOUGLAS\1807\PR0514131\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
5/15/2014 6:02:08 PM
QuestysRecordID
2439666
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Site Name <br />San Joa, `n County Environmental Health )partment <br />UnifWd Hazardous Waste Generator Mgram <br />VIOLATIONS <br />TANKS <br />(Refer to TIP -5 Tank Assessment Worksheet and Appendices) <br />61_ (CCR) Chapter 15- Failed to determine if tank is leaking or unfit . <br />62_ (CCR) Chapter 15 -Assessment not sufficient. <br />63_ (CCR) Chapter 15 -If found leaking or unfit, failed to comply. <br />64_ (CCR) Chapter 15- Failed to retain on-site required certification. <br />65_ (CCR) Chapter 15 -Failed to provide secondary containment. <br />66_ (CCR) Chapter 15 -Placed hazardous waste or reagents in tank system which caused the tank, containment <br />system or ancillary equipment to leak, corrode, rupture, or fail. <br />67_ (CCR) Chapter 15 -Failed to use controls and practices to prevent spillage and overflows from tank system. <br />68_ (CCR) Chapter 15 -Failed to prevent overtopping. <br />69_ (CCR) Chapter 15 -Failed to conduct daily inspections. <br />70_ (CCR) Chapter 15 -Failed to inspect cathodic protection system. <br />71_ (CCR) Chapter 15 -Failed to immediately remove tank system or secondary containment system that had leaked or <br />spilled. <br />72_ (CCR) Chapter 15 -During tank closure, failed to remove or decontaminated all waste residues, contaminated tank <br />system, soils, and manage them as hazardous waste. <br />73_ (CCR) Chapter 15 -Failed to manage ignitable or reactive waste properly. <br />74 (CCR) Chapter 15 -Failed to manage incompatible wastes properly. <br />UNIVERSAL WASTE <br />75._66273.14 (CCR) Small Quantity Handler did not mark or label the universal waste as specified in this section. <br />76._66273.15(a) (CCR) Small Quantity Handler had universal waste onsite for more than one year. <br />77.66273.15(c) (CCR) Small Quantity Handler was unable to demonstrate the length of time the universal waste has <br />been accumulated from the date it became a waste or was received. <br />78._66273.1 (CCR) Small Quantity Handler did not inform employees who handle universal waste proper handling and <br />emergency procedures. <br />79._66273.32 (CCR) Large Quantity Handler did not notify the EPA Regional Administrator to obtain an EPA ID <br />number. <br />80._66273.33 (CCR) Large Quantity Handler did not manage universal waste according to this section. <br />81._66273.34 (CCR) Large Quantity Handler did not label universal waste according to this section. <br />82._66273.35(a) (CCR) Large Quantity Handler had universal waste onsite for more than one year. <br />83. 66273.35(b) (CCR) Large Quantity Handler was unable to demonstrate the length of time the universal waste has <br />been accumulated from the date it became a waste or was received. <br />84._66273.36 (CCR) Large Quantity Handler did not inform employees who handle universal waste proper handling <br />and emergency procedures <br />85._66273.39 (CCR) Large Quantity Handler did not keep records of each shipment of universal waste according to <br />this section. ' <br />86.66273.82(b) (CCR) Cathode Ray Tube (CRT) handler that accepts more than 5 CRT devices per calendar year <br />from any offsite source failed to notify DTSC and the CUPA according to section. <br />87._66273.82(c) (CCR) CRT handler that generates 5,000 kilograms or more of CRT material per calendar year failed <br />to notify DTSC and the CUPA according to this section. <br />OTHER <br />88 See attached "Continuation -Official Inspection Report" for violation(s) not listed above. <br />SPCC <br />89_ 25270-25270.13 (HSC) Spill Prevention Control and Countermeasure Plan on site for aboveground <br />petroleum storage tank(s). <br />Page _ of <br />EHS Initialed by Date <br />9/30/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.