<br /> PERMIT TO OPERATE
<br /> Program Permit Permit
<br /> . Record Program
<br /> 82 Cade and Description Valid
<br /> P 518165 PT00118 -SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 111/2011 To 1273112011
<br /> a or Program
<br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code, Div.20,Chap.6.5,Art.2-13,
<br /> Sec.25100 et seq,and Title 22,California Code of Regulations,Chap.20:
<br /> — ------ _Ct --- --- -- ------- -------------------------
<br /> PR0505356 2300-UNDERGROUND STORAGE TANK FACILITY 1/1/2011 To 12131/2011
<br /> Underground Storage Tank Program
<br /> California Health and Safety Code, Div.20,Chap.6,7 and Title 23,California Code of Regulations,Chap, 16._
<br /> _ _______ p____Y___.___._.__ __ .. __. .__.
<br /> P/E Tank Tank Record ID Permit# Capacity Contents Permit Status. System Type Leak Detection
<br /> 2362 1 390005053560505357 PT0007940 10,000 DIESEL Active,billable DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 2 390005053560505358 PT0007937 6,000 MIDGRADE UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 3 390005053560505359 PT0007938 4,000 PREMIUM UNLEADED Active,billable DOUBLE WALLED Continuous Interstitial Monitoring
<br /> 2360 4 390005053560505360 PT0007939 10,000 REGULAR UNLEADED Active,billable DOUBLE WALLED continuous Interstitial Monitoring
<br /> Underground Storage Tank Permit Conditions
<br /> 1) The Permit to Operate will become void if Annual Peril Fees and Service Fees are not paid and/or the UST syster(s)fails to remain in compliance with these Permit Conditions.
<br /> 2) In order to maintain the operating permit,the owner and operator shall comply with die H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,w well as any conditions
<br /> established by San Joaquin County.
<br /> 3) If the TankOperator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both
<br /> the Tank Owner and tank Operator receive copy of the permit.
<br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(HF1D)and are considererd UST Permit Conditions. The approved
<br /> monitoring,response,and plot plans shall be maintained onsite with the permit
<br /> 5) The Permittee shall comply with rhe monitoring procedures referenced in this permit.
<br /> 6) The Permittee shall perform costing and preventive maintenance on all leak detection monituring equipment annually,or more frequently if specified by the equipment manufacturer,and
<br /> provide documentation of such servicing to this office.
<br /> 7) In the event of a spill,leak,or other unauthorized release,the Pannitee shall comply with the requirements of Tide 23 CCR,Chap. 16,Art.5,and the approved Emergency Response Plan.
<br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was
<br /> performed.
<br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change.
<br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or
<br /> revocation.
<br /> 11) Commotion,repair and/or removal permits are required from the ERD prior to any change,repair or removal of UST system equipment.
<br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this permit.
<br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency.
<br /> 14) A"Conditional"Permit may be revoked if corrections specified on the,inspection report are not completed by the dates) indicated.
<br /> .PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause.
<br /> PERMIT(s)Valid only for: PADDA, RUPINDER/SODHI,HOSHIAN
<br /> DBA: GEORGE'S BP MINI MART
<br /> Tank Owner: GALATSATOS, GEORGE
<br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES
<br /> Regulated Facility: GEORGES BP MINI MART Facility ID FA0006733
<br /> 18662 N HWY 88 AcccuntlD AR0009174
<br /> LOCKEFORD CA 95237 Issued 2/4/2011
<br /> 7028 not