My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
1820
>
2200 - Hazardous Waste Program
>
PR0540263
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 1:01:48 PM
Creation date
11/1/2018 8:36:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0540263
PE
2220
FACILITY_ID
FA0019717
FACILITY_NAME
Boretech Resources Recovery Engineering LLC
STREET_NUMBER
1820
STREET_NAME
INDUSTRIAL
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
000-050-868-9
CURRENT_STATUS
02
SITE_LOCATION
1820 INDUSTRIAL WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\I\INDUSTRIAL\1820\PR0540263\COMPLIANCE INFO PRE 2016.PDF
QuestysFileName
COMPLIANCE INFO PRE 2016
QuestysRecordDate
10/13/2016 9:43:42 PM
QuestysRecordID
3233882
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
809
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CERS Consolidated Emergency Response / Contingency Plan — Page 2 of 4 <br />Rev. Meant <br />I). ElW IRGENCY.:CONTARWENT AND CLEANUP PRQCEDURE�S <br />SPILL PREVENTION, CONTAINMENT, AND CLEANUP PROCFDURF.S: (Check all boxes that apply to indicate your procedures for containing spills, reteaaM <br />fires or explosions; andpreventing and mitigating associated harm to persons, property,and the environment <br />D. <br />® L MONITOR FOR LEAKS, RUPTURES, PRESSURE BUILD-UP, ETC.; <br />® 2. PROVIDE STRUCTURAL PHYSICAL BARRIERS (e.g., Portable spill containment walls); <br />(03. PROVIDE ABSORBENT PHYSICAL BARRIERS (e.g., Pads, pigs, pillows); <br />(94. COVER OR BLOCK FLOOR AND/ OR STORM DRAINS; <br />(95. BUILT-IN BERM IN WORK / STORAGE AREA; <br />® 6. AUTOMATIC FIRE SUPPRESSION SYSTEM; <br />® 7. ELIMINATE SOURCES OF IGNITION FOR FLAMMABLE HAZARDS (e.g. Flammable liquids, PrcpaneZ <br />® 8. STOP PROCESSES AND/OR OPERATIONS; <br />® 9. AUTOMATIC / ELECTRONIC EQUIPMENT SHUT-OFF SYSTEM; <br />® 10. SHUT-OFF WATER, GAS, ELECTRICAL UTILITIES AS APPROPRIATE; <br />® 11. CALL 9-1-1 FOR PUBLIC EMERGENCY RESPONDER ASSISTANCE / MEDICAL AID; <br />© 12. NOTIFY AND EVACUATE PERSONS IN ALL THREATENED AREAS; <br />© 13. ACCOUNT FOR EVACUATED PERSONS IMMEDIATELY AFTER EVACUATION CALL; <br />Q 14. PROVIDE PROTECTIVE EQUIPMENT FOR ON-SITE RESPONSE TEAM; <br />® 15. REMOVE OR ISOLATE CONTAINERS / AREA AS APPROPRIATE; <br />❑ 16. HIRE LICENSED HAZARDOUS WASTE CONTRACTOR; <br />© 17. USE ABSORBENT MATERIAL FOR SPILLS WITH SUBSEQUENT PROPER LABELING, STORAGE, AND HAZARDOUS WASTE DISPOSAL AS <br />APPROPRIATE; <br />® 18. SUCTION USING SHOP VACUUM WITH SUBSEQUENT PROPER LABELING, STORAGE, AND HAZARDOUS WASTF DISPOSAL AS <br />APPROPRIATE; <br />[119. WASH / DECONTAMINATE EQUIPMENT W/ CONTAINMENT and DISPOSAL OF EFFLUENT / RINSATE AS HAZARDOUS WASTE; <br />❑ 20. PROVIDE SAFE TEMPORARY STORAGE OF EMERGENCY -GENERATED WASTES; <br />[12 1. OTHER (Specify): DZ <br />77777777777-11 <br />EVACUATION <br />TIM FOLLOWING ALARM SIGNAL(S) WILL BE USED TO BEGIN EVACUATION OF THE FACILITY (CHECK ALL THAT APPLY): at <br />© 1. BELLS; <br />® 2. HORNS/SIRENS; <br />® 3. VERBAL (LE., SHOUTING); <br />❑ 4. OTHER 3 92. <br />THE FOLLOWING LOCATION(S) IS/ARE EVACUEE EMERGENCY ASSEMBLY AREA(S) (i.e., Front parking lot, specific street comer, etc.) m. <br />1. Front Parking Lot. <br />2. South east comer of builging on the sidewalk. <br />Note: The Emergency Coordinator must account for all on site employees and/or site visitors atter evacuation. <br />EVACUATION ROUTE MAP(S) POSTED AS REQUIRED 94. <br />Note: The map(s) must show primary and aRemate evacuation routes, usnergusrcy exits, and primary and altomate staging areas, and must be prominently posted <br />throughout the tgoili in It>cadons whore it will be visible to em to and visitors. <br />�<H F. At RANI ►E1vfNi- FOR EM RCE1L§*#PCE . <br />Rxplaaatioo of RegalremmG Advance arrangements with local fire and police departments, hospitals, and/or etnergency services oonttactors should be [Wade as <br />appropriate for your facility. You may determine that such arrangements are not necessary. <br />ADVANCE ARRANGEMENTS FOR LOCAL EMERGENCY SERVICES (Check one of the following) Ft. <br />❑ 1. HAVE BEEN DETERMINED NOT NECESSARY; or <br />® 2. THE FOLLOWING ARRANGEMENTS HAVE BEEN MADE (Specify): <br />Auto alarm for fire and Burglary with Fire department and Police department. <br />
The URL can be used to link to this page
Your browser does not support the video tag.