Laserfiche WebLink
Sacra uin County Environmental Healt& artment <br />ka <br /> ed HAZARDOUS WASTE GENERATOR PROGRAM INSPECTION REPORT <br /> Address: Ins <br /> Co a Section VIOLATIONS <br /> 25160(d HSC Transp a hazardous waste without a manifest <br /> 25163(a)HSC Transp hazardous waste or transferred HW to a transporter without valid registration. <br /> 25160.2(c)(2)HSC Offered ineligible waste streams to be transported usingconsolidated manifest. <br /> 25160.2(b)(4)HSC Consolidated manifest receipts failed to contain complete information. <br /> 25250.23 HSC Transported used oil and not reistered as a hazardous waste hauler. <br /> 66263.17 a CCR Trans orted hazardous waste without receivin ID Number and re istration cert from DTSC. <br /> 66263.23 b CCR Delivered hazardous waste to an unauthorized facili . <br /> 66265.17 CCR Failed to mana a incompatible waste in containers proper) . <br /> 66265.199 CCR Failed to mana a incom alible waste in tanks properly. <br /> 25250.7 HSC Contaminated used oil with other hazardous waste. <br /> 66266.81 b CCR Dama ed lead acid batteries not roper) mana ed and labeled. <br /> 66265.191 a CCR Failed to determine if HW tank is leaking or unfit. <br /> 62 66265.191 b CCR HW tank assessment not sufficient. <br /> to 63 66265.191 d CCR If HW tank found leakingor unfit,failed to comp) with 66265.196. <br /> Z 64 66265.192 CCR Failed to retain on-site required cerlificabon for HW tanks. <br /> 65 66265.193 CCR Failed to provide secondary containment for HW tank. <br /> Lu Placed hazardous waste or reagents in tank system that caused the tank,containment <br /> y 66 66265.194(a)CCR system or ancilla equipment to leak corrode,rupture,or fail. <br /> Q <br /> 3 67 66265.194(b)CCR Failed to use controls and practices to prevent spillage and overflows from tank system. <br /> 68 66265.194(b)(3)CCR Failed to prevent overtopping from HW tank. <br /> O 69 66265.195(a)CCR Failed to conduct daily inspections of HW tank. <br /> z 7066265.195(b)CCR Failed to inspect HW tank cathodic protections stem. <br /> r� 71 66265.196 CCR Failed to immediately remove tank/secondary containments stem that had leaked orspilled. <br /> x 72 66265.197 CCR Tank closure,failed to remove/decon all waste and manage them as HW. <br /> 73 66265.198 a b CCR Failed to manage ignitable or reactive waste properly. <br /> 74 66265.199 ay(b)CCR Failed to manage incompatible wastes property. <br /> Small Quantity Handler(SQH)did not manage UW according to these sections(a}(c),[UW <br /> 75 66273.13 CCR Electronic Device(UW ED)(d):Containment(1), Notification(2),SQ Handler Standards(3), <br /> Zoning Residuals(5),M mt Standards 6 Treatment Standards(7).] <br /> 76 66273.14 CCR Small Quantity Handler did not mark universal waste according to this section. <br /> 77 66273.15 CCR SQH had universal waste onsite for more than one year(a)or was unable to demonstrate the <br /> LU length of time UW was accumulated from the date it became a waste or was received.(c) <br /> u) 78 66273.16 CCR SQH did not inform employees who handle UW proper handling and emergency rocedures. <br /> 3 79 66273.32 CCR LQH did not notify the EPA RA to obtain an EPA ID#, see UWED subsection a 3 A)-C . <br /> 80 66273.33 CCR Large Quantity Handler did not manage universal waste according to these sections(a)-(c) <br /> to 81 66273.33(d)CCR Containment(1),Notification(2),LQ Handler Standards(3),Zoning(4), Residuals(5), Mgmt- <br /> Lu Standards 6 Treatment Standards(7). <br /> >_ 82 66273.34 CCR Large Quantity Handler did not label universal waste according to this section. <br /> Z LQH had UW onsite for more than 1 year(a)or was unable to demonstrate the length of time <br /> 83 66273.35 CCR <br /> the UW has been accumulated from the date it became a waste or was received. c <br /> 84 66273.36 CCR LOH did not inform employees who handle UW proper handling and emergency rocedures. <br /> 85 66273.39 CCR/66273.19 CCR LQH/SQH did not keep records of each shipment of universal waste according to this section. <br /> 86 66273.82 CCR Cathode Ray Tube CRT handler accepts offsite source failed to notify DTSC 30 days prior. <br /> 87 1 66273.83 CCR CRT Waste Management. <br /> SQG's(generates less than 1000 kg/mo) <br /> 88 66262.34(d)CCR& Stored hazardous waste onsite greater than 180 days <br /> 25123.3(h)(1)HSC <br /> 89 66262.34 d 1 CCR Accumulated more than 6,000 kg onsite at one time. <br /> 90 66262.34(dX2)CCR Modified emergency coordinator information lacking or insufficient[as referenced by CFR <br /> 262.34 d and CFR e& <br /> OTHER <br /> 91 66261.7(f)CCR An empty HW or Haz Mat container(larger than 5 gallons)was not marked with the date it <br /> was emptied/not managed within one year of being emptied. <br /> 9225217.1 HSC Liquid latex paint was disposed of,or attempted to be disposed of,to land or water. <br /> 93 See attached"Continuation-Official Inspection Report"for violations not listed above. <br /> 94-1 1 1 25270-25270.13 HSC Spill Prevention Control and Countermeasure Plan not onsite for Petroleum AST's. <br /> UIC I Septic ystern:_Serves>20 persons/day _Receives other than sanitary waste _Dry wells/French Drains Onsite <br /> EHD Inspector: eived Bz: Tifle: <br /> EHD 22-02-004 Rev 5108 600 EAST MAIN STREET,STOCKTON,CA 95202(209)468-3420 Page 2 <br />