My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GUILD
>
850
>
2200 - Hazardous Waste Program
>
PR0541230
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 10:47:06 AM
Creation date
11/1/2018 8:54:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0541230
PE
2247
FACILITY_ID
FA0023618
FACILITY_NAME
OMNICARE OF NORTHERN CALIFORNIA
STREET_NUMBER
850
Direction
S
STREET_NAME
GUILD
STREET_TYPE
AVE
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
850 S GUILD AVE STE 100
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\G\GUILD\850\PR0541230\COMPLIANCE INFO 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2016
QuestysRecordDate
6/6/2017 3:54:42 PM
QuestysRecordID
3201539
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> hone: 209)468-3420 Fax: (209) 468-3433 Web:www.sigov.orQ/ehd <br /> :RCR:A :LarTg:eQuan(tity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Omnicare of Northern California 850 S GUILD AVE, Lodi September 26, 2016 <br /> Treatment, Transport, and Disposal <br /> 202 HSC 25189.5(a) Disposed or caused disposal of HW at an unauthorized point r V o R COS <br /> 203 HSC 25189.5(c) Transported or caused transportation of hazardous waste to an unauthorized point ❑V ❑R o COS <br /> 204 HSC 25201(a) Failed to obtain a permit to treat hazardous waste ❑V n R ❑COS <br /> 205 HSC 25250.7 Failed to manage used oil contaminated with other hazardous waste as hazardous waste ❑V ❑R n COS <br /> 206 HSC 25160.2(c)(2) Waste stream or generator not eligible to use consolidated manifesting procedure ❑V ❑R n COS <br /> 207 HSC 25144.6(b) Failure to properly manage reusable soiled textile materials c V ❑R ❑COS <br /> Preparedness and Prevention <br /> 301 CCR 66265.31 Facility not maintained to minimize the release of a hazardous waste ❑V o R ❑COS <br /> 302 CCR 66265.32 Failed to maintain required emergency equipment ❑V in R o COS <br /> 303 CCR 66265.33 Failed to maintain all communication or alarm systems,spill control,or decontamination equipment ❑V ❑R ❑COS <br /> 304 CCR 66265.35 Failed to maintain adequate aisle space for unobstructed response to emergencies ❑V ❑R ❑COS <br /> 305 CCR 66265.17(a) Failed to protect containers from sources of ignition or reaction o V n R n COS <br /> Container Management <br /> 401 CCR 66265.171 Failed to store hazardous waste in a container that is in good condition in V ❑R ❑COS <br /> 402 CCR 66265.172 Failed to store hazardous waste in a compatible container in V ❑R ❑COS <br /> 403 CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous waste n V ❑R ❑COS <br /> 404 CCR 66265.174 Failed to inspect hazardous waste storage areas at least weekly ❑V ❑R ❑COS <br /> 405 CCR 66265.176 Failed to store ignitable or reactive waste containers at least 50 feet from the property line ❑V ❑R ❑COS <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied ❑V ❑R ❑COS <br /> 407 CCR 66265.17(b), Failed to manage incompatible wastes in containers properly in V ❑R ❑COS <br /> 66265.177 <br /> 408 CCR 66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator ❑V u R ❑COS <br /> 409 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste stream ❑V ❑R o COS <br /> 410 CCR 66262.34(a)(1), Failure to comply with hazardous waste container air emission requirements o V ❑R ❑COS <br /> 66262.178 <br /> Tank Management <br /> 501 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks ❑V n R ❑COS <br /> 502 CCR 66265.192(a) Failed to comply with new hazardous waste tank system assessment requirements o V in R ❑COS <br /> 503 CCR 66265.192(k) Hazardous waste tank assessment is incomplete ❑V ❑R c COS <br /> 504 CCR 66265.192(1)/(m) Failed to notify EHD before replacing identical or equivalent equipment ❑V ❑R c COS <br /> 505 CCR 66265.193 Hazardous waste tank system lacks secondary containment ❑V n R ❑COS <br /> 506 CCR 66265.194 Failed to maintain tanks for storage of incompatible materials or prevent spills and overfills ❑V ❑R ❑COS <br /> 507 CCR 66265.195 Failed to conduct daily inspections of hazardous waste tank system and maintain records onsite c V ❑R ❑COS <br /> 508 CCR 66265.195(b) Failed to inspect HW tank cathodic protection system ❑V ❑R ❑COS <br /> 509 CCR 66265.196 Failed to immediately respond to spills and leaks from hazardous waste tank system ❑V ❑R a COS <br /> 510 CCR 66265.197 Failed to property close a hazardous waste tank system ❑V ❑R ❑COS <br /> FA0023618 PRO541230 SCO01 09/26/2016 <br /> EHD 22-03 Rev.09/22/16 Page 2 of 4 RCRA Large Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.