SEP-26-2006 13:29 Serl•'^e Station Systems 408 938 8888 P.05 <br /> •Once in the open position, MLD remains open during product delivery to pressures as low as 1 <br /> psi.Therefore,the MLD will not close when several nozzles are open at the same time. <br /> •3rd parry certified to comply with US EPA requirements 280.41 (B)and 280.44(A)for continuous <br /> monitoring of pressurized piping. <br /> • UL listed for installation in all 4" FE Petro pumps and most competitive makes. <br /> •Compatible with all blends of motor fuels including alcohol blends from 0 to 100%ethanol or <br /> methanol, 20% MTBE or ETBE with 80%gasoline, or 17%TAME with 83%gasoline as well as <br /> diesel,fuel oil, avgas,jet fuel, and kerosene. <br /> •MLD signals a line leak by allowing less than 3 GPM (11 .4 LPM) restricted flow rate, at leak sizes <br /> of 3 GPH or greater. Leaks of less than 3 GPH are indicated by the leak detector taking longer than <br /> 2 to 3 seconds to open. <br /> •Time required to make a line test is 2 to 3 seconds when no line leaks exist and air is purged from <br /> piping. <br /> •Maximum static head on MLD is approximately 10 feet (3.28m)from MLD to the highest point in <br /> the piping system. <br /> •Weight: 9.2 pounds (4.2 kg). <br /> •Minimum height requirement from 2" NPT port to manhole cover for clearance is 9" (22.9 cm). <br /> Maximum product viscosity is 70 SSU at 60° F(15.60 G). <br /> OPERATING CHARACTERISTICS. <br /> The FE Petro STP-MLD leak detector is a three position, pressure-sensing, piston operated valve <br /> designed to continuously monitor the piping by indicating any leakage in the piping between the <br /> discharge and the submersible pump and the solenoid valve in a service station dispenser. <br /> When the submerged pump is turned on after the system pressure has dropped significantly below <br /> the normal static system pressure, three GPH (at 10 psi) is metered through the STP-MLD into the <br /> piping system. If a leak is present that equals or exceeds this amount, as much product escapes <br /> from the system as is metered through the STP-MLD. Under this condition, pressure cannot build <br /> up in the piping system.When a nozzle is opened, a poppet in the STP-MLD moves to a position <br /> that restricts the flow to 2 GPM. This is the indication to the operator that a leak is present. If there <br /> are no leaks, pressure rapidly builds in the system forcing the STP-MLD to open to the full-flow <br /> position. In a system with no leaks, it takes approximately three seconds for a complete test. No <br /> further line testing takes place until the line pressure drops significantly below the normal static <br /> system pressure. <br /> 1.The Tripped or Bottom 2.Leak Sensing Position 3. Non-Leak or Full Flow <br /> Position Position <br /> 1 <br /> :ins... <br /> http://www.fepetro.com/english/ML.D.HTML 9/26/06 <br />