Laserfiche WebLink
MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGEN <br /> TANK TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE ATES METAL PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD 8020 (MTBE ICAp/ 8270 <br /> 8260 8260 8260 8240 7420 8260 TBA,DIPE, AES or 8080 <br /> 8260 7421 TTAME) AA <br /> 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK.FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WASTE\ <br /> USED OIL X X X X X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW 846 are <br /> specifically noted below. Refer to the"SWRCB LUFT Field Manual",Appendix D (B), Table 3-5 on page A20 for minimum detection <br /> limits for motor vehicle fuel (gasoline and diesel). Refer to "Tri-Regional Board Staff Recommendations for Initial Evaluation and <br /> Investigation of UST's" for the waste and motor oil minimum detection limits. Detection Limits that remain below the MCL,STLC or <br /> Allowable Limit of the contaminant in question will be accepted,however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G, Total Petroleum.Hydrocarbon,.Gasoline,GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D':Tofal.Pe#roleum Hydrocatlion;.l7iesel;GC/FID'(3550),$0k5 m4d.of <br /> BTX&EBenzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/M[S 8240 or 8260 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPE,&TBA GC/M[S 8260(For MTBE screen only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. Metals: <br /> Cadmium,Chromium III and V1,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed columns;a <br /> packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have been characterized and proper QA/QC is followed. For <br /> drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the detection <br /> ]units are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.PHS-EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 05/09/00) <br /> 5 <br />