My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2007-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2019 4:45:49 PM
Creation date
11/1/2018 10:33:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2007-2011
FileName_PostFix
2007-2011
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0. Results of Testing/Servieing <br />Software Version Installed: 4:2-1 . 0 <br />Com lete the followin checklist: <br />Kt Yes 0 No* Is the audible alarm operational? <br />a Yes CI No Is the visual alarm operational? ..,... <br />0 Yes 0 No* Were all sensors visually ins_pected, functionally tested, and confirmed operational? <br />El- Yes CI No Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />U Yes LI No* <br />El N/A <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />operational? <br />0 Yes a No* <br />0 N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut-down? (Check all that apply) 0 Sump/Trench Sensors; U Dispenser Containment Sensors. <br />Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; No. <br />0 Yes <br />FLA- PPee <br />0 No* <br />ig. N/A <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />0 Yes* A No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />U Yes* ES No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) 0 <br />Product; EJ Water. If yes, describe causes in Section E, below. <br />Er Yes 0 No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />tEl, Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: 7 t5 1/7" U565 4,004.4-t- (,jE 7 rç Ria 72/e-e- <br />-T-Ago4 PaSin cwa -r- Ocrtk) ir-6 s 11 ft-4e-it-IS . <br />Page 2 of 3 03/01
The URL can be used to link to this page
Your browser does not support the video tag.