Laserfiche WebLink
RS -232 END OF MESSAGE <br />DISABLED <br />IN -TANK SETUP <br />RECEIVER SETUP: <br />- - - - - - - - <br />AUTO DIAL ALARM SETUP <br />_ <br />- - - <br />T 1:DIESEL <br />D 1:VEEDER ROOT MONITOR <br />19288328512 <br />D 1:VEEDER ROOT MONITOR <br />PRODUCT CODE <br />1 <br />THERMAL COEFF :.000450 <br />RCVR TYPE: FACSIMILE <br />PORT NO: 3 <br />LIQUID SENSOR ALMS <br />TANK DIAMETER <br />120.00 <br />RETRY NO: 3 <br />ALL:FUEL ALARM <br />TANK. PROFILE <br />1 PT <br />RETRY DELAY: 3 <br />ALL:SENSOR OUT ALARMFULL <br />VOL <br />20073 <br />CONFIRMATION REPORT: ON <br />ALL:SHORT ALARM <br />D 2:JAMESO <br />ISD SITE ALARMS <br />FLOAT SIZE: 4.0 <br />IN. <br />14054633735 <br />ISD STAGE I WARN <br />WATER WARNING <br />2.0 <br />RCVR TYPE: COMPUTER <br />ISD GROSS FRES WARN <br />HIGH WATER LIMIT: <br />3.0 <br />PORT NO: 2 <br />ISD GROSS PRES FAIL <br />RETRY NO: 3 <br />ISD DEGRD PRES WARN <br />MAX OR LABEL VOL: <br />20073 <br />RETRY DELAY: 3 <br />ISD DEGRD PRES FAIL <br />OVERFILL LIMIT <br />90% <br />CONFIRMATION REPORT: OFF <br />ISD VAPOR LEAK WARN <br />185 <br />ISD VAPOR LEAK FAIL <br />HIGH PRODUCT <br />95% <br />D 3:KEVINN <br />ISD VP FRES WARN <br />1900669 <br />9 <br />14052422691 <br />ISD VP PRES FAIL <br />DELIVERY LIMIT <br />15% <br />RCVR TYPE: COMPUTER <br />ISD VP STATUS WARN <br />1010 <br />PORT NO: 2 <br />ISD VP STATUS FAIL <br />RETRY NO: 3 <br />MISSING RELAY SETUP <br />LOW PRODUCT <br />2000 <br />RETRY DELAY: 3 <br />MISSING HOSE SETUP <br />LEAK ALARM LIMIT: <br />99 <br />CONFIRMATION REPORT: OFF <br />MISSING TANK SETUP <br />SUDDEN LOSS LIMIT: <br />99 <br />MISS VAPOR FLOW MTR <br />TANK. TILT <br />0.00 <br />MISS VAPOR PRES SEN <br />PROBE OFFSET <br />0.00 <br />MISSING VP INPUT <br />ISD SETUP WARN <br />ISD SETUP FAIL <br />SIPHON MANIFOLDED TANKS <br />ISD SENSOR OUT WARN <br />TO: 02 <br />ISD SENSOR OUT FAIL <br />LINE MANIFOLDED TANKS <br />PC -ISD FAILURE <br />TO: 02 <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT WARN <br />LEAK MIN PERIODIC: <br />035 <br />AUTO DIAL TIME SETUP: <br />ALL:GROSS COLLECT FAIL <br />0 <br />ALL:DEGRD COLLECT WARN <br />ALL:DEGRD COLLECT FAIL <br />LEAK MIN ANNUAL <br />0% <br />D 1:VEEDER ROOT MONITOR <br />ALL:FLOW COLLECT WARN <br />0 <br />DIAL ON DATE <br />ALL:FLOW COLLECT FAIL <br />AUG 26, 2008 <br />DIAL TIME : DISABLED <br />ALL:AIRFLOW MTR SETUP <br />PERIODIC TEST TYPE <br />RECEIVER REPORTS: <br />STANDARD <br />VAPOR FLW MTR ALMS <br />D 2:JAMESO <br />ALL:CHK VAPOR FLOW MTR <br />ANNUAL TEST FAIL <br />DIAL ON DATE <br />AUG 26. 2008 <br />FMC ALARMS <br />ALARM DISABLED <br />DIAL TIME : DISABLED <br />VP RUNTIME FAULT <br />PERIODIC TEST FAIL <br />RECEIVER REPORTS: <br />VP EMISSIONS WARN <br />ALARM DISABLED <br />VP EMISSIONS FAIL <br />D 3:KEVINN <br />VP PRESSURE WARN <br />GROSS TEST FAIL <br />DIAL ON DATE <br />VP PRESSURE FAIL <br />ALARM DISABLED <br />AUG 26, 2008 <br />VP DUTY CYCLE WARN <br />DIAL TIME : DISABLED <br />VP DUTY CYCLE FAIL <br />ANN TEST AVERAGING: <br />OFF <br />RECEIVER REPORTS: <br />FMC SETUP FAIL <br />PER TEST AVERAGING: <br />OFF <br />PMC SENSOR FAULT <br />D 2:JAMESO <br />TANK: TEST NOTIFY: <br />OFF <br />LIQUID SENSOR ALMS <br />TNK TST SIPHON BREAK OFF <br />ALL:FUEL ALARM <br />DELIVERY DELAY <br />3 MIN <br />ALL:SENSOR OUT ALARM <br />PUMP THRESHOLD <br />10.00% <br />ALL:SHORT ALARM <br />v <br />ISD SITE ALARMS <br />ISD STAGE I WARN <br />ISD GROSS PRES WARN <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES WARN <br />D 3:KEVINN <br />- NO ALARM ASSIGNMENTS - <br />