My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO 2007-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2019 4:45:49 PM
Creation date
11/1/2018 10:33:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2007-2011
FileName_PostFix
2007-2011
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
194
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> D. Results of Testing/Servicing • <br /> Software Version Installed: <br /> 329,00 <br /> Com tete the followin I checklist: <br /> ® Yes ❑ No- Is the audible alarm operational? <br /> ® Yes ❑ No' Is the visual alarm operational? <br /> ® Yes ❑ No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No- Were all sensors installed at lowest point of Secondary ry containment and positioned so that other equipment will not interfere with their proper <br /> ❑ Yes ❑ No- It alarms are relayed to a remote monitoring station,is all communications equipment <br /> ® N/A <br /> ❑ Yes ® No' (e.g,,modem)operational? <br /> For pressurized piping systems,does the turbine automatically shut down if the piping secunda <br /> ❑ N/A fails to operate, or n electrically disconnected? If yes: which sensors initiate ifhe positive shut-down? (Check al/that <br /> Sensors; p secondary containment monitoring system detects a leak, <br /> ❑Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? app/yl SUMP/Trench <br /> ❑ Yes ❑ No' For tank systems that utilize the monitoring system as the rima ❑Yes; ®No. <br /> ® N/A installed),is the overfill warning alarm visible and audible at the tank fill poll nt(s)and operating warning device ope no mechanical overfill prevention valve is <br /> does the alarm trigger? % P g properly? If so,at what percent of tank capacity <br /> ❑ Yes ® No Was any monitoring eceipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> andModel oriel for all rec ace.ment parts in a If e,below. <br /> ❑Yes' 0 No Was .quid found insi.-e&,j secondary con:a:nment systems designed as dry systems? (Check alt that apply) <br /> = croduct; ❑Wa•ar I`res,describe ca;:ses in Section E,below. <br /> ® Yes as monitoring sys:e—Se!,;p reviewed o ensure proper settings?All ch set up reports,if applicable <br /> ❑ Yes ❑ w.' s a. monitoring equip-e,z operations' _ manufacturer's specifications? <br /> `In Section E besoiw,desc-roe how and when these deRclill were or will be corrected. <br /> E. comments: SITE DOES LINE TESTING IN LUE OF POSITIVE SHUTDOWN. <br /> 2/21/07 <br /> Page 2 of 4 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.