My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LONGE
>
7910
>
2200 - Hazardous Waste Program
>
PR0516115
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:37:59 AM
Creation date
11/1/2018 11:37:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0516115
PE
2220
FACILITY_ID
FA0012466
FACILITY_NAME
PREMIER FINISHING
STREET_NUMBER
7910
Direction
S
STREET_NAME
LONGE
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
7910 S LONGE
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LONGE\7910\PR0516115\COMPLIANCE INFO 2002 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2015
QuestysRecordDate
11/13/2017 7:55:10 PM
QuestysRecordID
3725096
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
562
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Affik <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.si oq v.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PREMIER FINISHING 7910 S LONGE , STOCKTON April 26, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 609 HSC 25143.2, 25143.9 Failed to meet requirements for claimed excluded recyclable materials. <br /> Waste acetone is claimed to be an excluded recyclable waste but does not meet the requirements to be considered <br /> so. One 55-gallon blue container of waste acetone located inside the indoor paint supply mixing room was labeled <br /> as"Excluded Recyclable Material" and had a full hazardous waste label identifying it as "hazardous waste". A waste <br /> may be considered an excluded recyclable material if recycled by any of the following methods <br /> 1. used or reused as an ingredient in an industrial process to make a product if the material is not being <br /> reclaimed, <br /> 2. used or reused as a safe and effective substitute for commercial products if the material is not being <br /> reclaimed, <br /> 3. returned to the original process from which the material was generated, without first being reclaimed, if the <br /> material is returned as a substitute for raw material feedstock, and the process uses raw materials as principal <br /> feedstocks, <br /> And shall meet all of the following conditions: <br /> 1, the material is recycled and used at the same facility at which the material was generated, or by the same <br /> corporate entity, <br /> 2. the material is recycled within the applicable generator accumulation time, <br /> 3. the material is managed in accordance with all applicable requirements for generators of hazardous wastes, <br /> 4. if the material is held in a container or tank, the container or tank is labeled, marked, and placarded in <br /> accordance with the departments hazardous waste labeling, marking, and placarding requirements which are <br /> applicable to generators, except that the container or tank shall be labeled or marked clearly with the words <br /> "Excluded Recyclable Material" instead of the words"Hazardous Waste," <br /> 5. if the material is used oil, the containers, aboveground tanks, and fill pipes used to transfer oil into <br /> underground storage tanks shall also be labeled and clearly marked with the words"Used Oir', <br /> 6. the owner or operator of the business location where the material is located has a business plan that meets <br /> the following minimal requirements: emergency response plans and procedures, which specifically address the <br /> material or that meets the emergency response and contingency requirements which are applicable to generators of <br /> hazardous waste, and <br /> 7. the material shall be stored and handled in accordance with all local ordinances and codes. <br /> Immediately begin managing this material as hazardous waste or demonstrate to the EHD that the material meets <br /> the excluded recyclable material requirements (label as appropriate). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br /> complete report which replaces the initial checklist. Facility inspection was initiated on 4-26-2017 and was <br /> completed on 4-27-2017. Elena Manzo and Stacy Rivera of EHD were accompanied by Tom Wise and Craig <br /> Walters at the time of facility walk through. One sample of the filter cake press material was collected on <br /> 4-27-2017 from the filter press located near the "stainless" holding tank, results were not yet available at the <br /> time of this report preparation. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> FA0012466 PRO516115 SCO01 04!2612017 <br /> EHD 22-01 Rev.09/22/16 Page 11 of 12 'Small Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page