Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.s�gov.org/ehd <br /> ME <br /> Is <br /> Facility Name: Facility Address: Date: <br /> PREMIER FINISHING 7910 S LONGE , STOCKTON April 26, 2017 <br /> A fN. <br /> amp y <br /> Item# Remarks <br /> 116 HSC 25143.10 Failed to provide information for 3100 kg/mo recyclable material to claim the exclusion or exemption. <br /> Waste acetone and waste paint stripper (Jem Strip 427) are being recycled onsite and all the required information to <br /> claim the exclusion or exemption has not been submitted, according to reviewed records in December of 2016, this <br /> facility recycled 208 gallons of acetone. To claim an exclusion or exemption from classifying this as a waste, the <br /> following information shall be submitted every two years-. <br /> -name, site address, mailing address, and telephone number of the owner or operator of the facility that recycles <br /> the material; <br /> - name and address of the generator of the recyclable material,- <br /> -documentation that the requirements of any exemptions or exclusions pursuant to HSC 25143.2 are met. <br /> Submit statements or documentation showing that above materials meet the recycling exemption of HSC 25143.2 <br /> and which subsection applies. Immediately provide all required information for every recyclable material that you <br /> wish to claim the exclusion or exemption and provide that information every two years. Also, submit the Recyclable <br /> Materials Report in CERS, and maintain recycling records onsite for review during inspection. If the required <br /> information cannot be provided, the materials must immediately be handled as a hazardous waste. <br /> This is a Class 11 violation. <br /> 117 HSC 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 6-16-2014 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted 30 days from the receipt <br /> of the full inspection report. This information has not been received in its entirety resulting in a non-compliant status <br /> for this facility. An operator that receives an inspection report shall have 30 days to submit a written response that <br /> includes a statement documenting corrective actions taken or proposing corrective actions which will be taken, refer <br /> to the 6-16-2014 inspection and the follow up correspondence for the outstanding violations. Ensure that a written <br /> response documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection <br /> report. <br /> This is a Class II violation. <br /> FA0012466 PRO516115 SCO01 04/26/2017 <br /> EHD 22-01 Rev.09/22/16 Page 7 of 12 Small Quantity Hazardous waste Generator OIR <br />