My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2200 - Hazardous Waste Program
>
PR0220082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 2:12:46 PM
Creation date
11/1/2018 12:04:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0220082
PE
2220
FACILITY_ID
FA0000214
FACILITY_NAME
PILKINGTON NORTH AMERICA INC PLANT 10
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330-9739
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\PR0220082\COMPLIANCE INFO 1989 - 1992.PDF
QuestysFileName
COMPLIANCE INFO 1989 - 1992
QuestysRecordDate
9/22/2017 9:10:01 PM
QuestysRecordID
3256138
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
954
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PILKINGTON NORTH AMERICA INC PLANT 10 1500 E LOUISE AVE LATHROP November 09 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> The eyewash station on site is being inspected and tested monthly, according to the tag attached to the station. The <br /> instructions on the eyewash state that testing should be conducted weekly. All facility communications or allarm <br /> systems, fire protection equipment, spill control equipment, and decontamination equipment, where required, shall be <br /> tested and maintained as necessary to assure its proper operation in time of emergency. Immediately begin <br /> conducting required testing in accordance with equipment and manufacturer instructions. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by December 9, 2017. <br /> Please be aware as of January 1, 2013, all businesses are required to submit all hazardous materials information <br /> online to the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov. Be sure to include <br /> your hazardous waste activity in the Businesses Activities section in CERS in addition to any other relevant <br /> activities and required fields. <br /> Wastes generated at this facility: Used oil, lead acid battery spill clean up <br /> Documents provided: Return to Compliance Certification form, Modified Contingency Plan template <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: November 09, 2017 Inspector: Inspector Phone: <br /> Printed Name and Title: STACY RIVERA, Senior REHS (209)468-3440 <br /> Cyndi Ward, EH&S Director <br /> FA0000214 PR0220082 SCO01 11/09/2017 <br /> EHD 22-01 Rev.09/22/16 Page 7 of 7 Small Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.