My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
3460
>
2200 - Hazardous Waste Program
>
PR0517826
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2020 4:40:47 PM
Creation date
11/1/2018 12:11:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0517826
PE
2228
FACILITY_ID
FA0013605
FACILITY_NAME
PREMIER CHRYSLER DODGE JEEP RAM OF TRACY
STREET_NUMBER
3460
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21205061
CURRENT_STATUS
01
SITE_LOCATION
3460 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAGLEE\3460\PR0517826\COMPLIANCE INFO 2002 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2002 - 2016
QuestysRecordDate
6/9/2017 5:39:35 PM
QuestysRecordID
3424524
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
231
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Tracy Chrysler Jeep <br /> Hydrostatic Calculation <br /> Used Oil Tank <br /> Tank Design Rectangular, Horizonte <br /> Material of Construction Steel <br /> Yield Strength, psi 36000.00 <br /> Design Tensile Strength, psi 33000.00 <br /> Depth of Oil 33.00 <br /> Area of wetted wall, ft2 16.50 <br /> S.G Contents 0.92 <br /> Average Pressure, Ib/ft2 78,94 <br /> Resultant Force, lbs 1302.44 <br /> Location of Resultant Force, from bottom, in 10.60 <br /> Moment, ftlbf of R 1150.49 <br /> Resisting Moment at top of tank, B 1150.49 <br /> Resisting Moment arm at B, ft 3.00 <br /> Resisting Force at B 383.50 <br /> Resisting Force at bottom of tank at A 918,95 <br /> Area of tank bottom under tension, in2 7.80 <br /> Tensile stress at tank wall bottom corner, psi 117.89 <br /> Design Tensile Strength > Applied Tensile Strength <br /> ' Factor of Safety 279.93 <br /> Tank Design Okay for Hoop Stress <br /> Buckling <br /> b 37.00 <br /> d 30.00 <br /> b1 36.70 <br /> ' <br /> dill 29.70 <br /> Zx, in3 231.82 <br /> F, lbs 2391.00 <br /> Moment Arm 18.50 <br /> Mp, in Ibf 44233.50 <br /> stress applied by earthquake, psi 1206.00 <br /> design stress, psi 33000.00 <br /> design stress > applied stress, Tank will not buckle <br /> during quake <br /> Factor of Safety 27.36 <br /> Tank Design, Okay for Buckling <br /> Figure 8. Hydrostatic Calculation shows tank has sufficient strength for present use. <br /> Review of the Steel Tank Institutes, SP001 tank inspection standard indicates the <br /> tank is a category 1 tank and requires only periodic external inspection. <br /> Integrity testing findings: Based on the above noted integrity test and the <br /> results obtained from that test, the tank has sufficient integrity for its intended <br /> use. Initials: <br />�t <br />' Tracy Chrysler Jeep 9 Used Oil Tank <br />
The URL can be used to link to this page
Your browser does not support the video tag.