My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2200 - Hazardous Waste Program
>
PR0514502
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:43:56 AM
Creation date
11/1/2018 1:07:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514502
PE
2228
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\3515\PR0514502\COMPLIANCE INFO 1985 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 1985 - 2016
QuestysRecordDate
8/31/2017 7:31:33 PM
QuestysRecordID
3617636
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sann County Environmental Hepartment <br />Urii k Hazardous Waste Generato gram <br />Site Name 01 ! <br />Address <br />VIOLATIONS <br />TANKS <br />Existing systems (installed before 7114/86) <br />61 66265.191(a) (CCR) Failed to determine if tank is beaking or unfit . <br />62 66265.191(b) (CCR) Assessment not sufficient. <br />63 66265.191(d) (CCR) if found leaking or unfit, failed to comply with 66265.196. <br />New systems (installed after 7/14/86) <br />64 66265.192 (CCR) Failed to retain on-site required certification. <br />65 66265.193 (CCR) Failed to provide secondary containment. <br />66 66265.194(a) (CCR) Placed hazardous waste or reagents in tank system which caused the tank, containment <br />system or ancillary equipment to leak, corrode, rupture, or fail. <br />67 66265.194(b) (CCR) Failed to use controls and practices to prevent spillage and overflows from tank system. <br />68 66265.194(b)(3) (CCR) Failed to prevent overtopping. <br />69 66265.195(a) (CCR) Failed to conduct daily inspections. <br />70 '66265.195(b) (CCR) Failed to inspect cathodic protection system. <br />71 66265.196 (CCR) Failed to immediately remove tank system or secondary containment system that had leaked or <br />spilled. <br />72 66265.197 (CCR) During tank closure, failed to remove or decontaminated all waste residues, contaminated tank <br />system, soils, and manage them as hazardous waste. <br />73 66265.198(a)and/or(b) (CCR) Failed to manage ignitable.or reactive waste properly. <br />74 66265.199(a)and/or(b) (CCR) Failed to manage incompatible wastes properly. <br />UNIVERSAL WASTE <br />75. 6627314 (CCR) Small Quantity Handler did not mark or label the universal waste as specified in this section. <br />76. 662.73.15(a) (CCR) Small Quantity Handler had universal waste onsite for more than one year. <br />77. 66273.15(c) (CCR) Small Quantity Handler was unable to demonstrate the length of time the universal waste has <br />been accumulated from the date it became a waste or was received. <br />78. 66273.1 (CCR) Small Quantity Handler did not inform employees who handle universal waste proper handling and <br />emergency procedures. <br />79. 66273.32 (CCR) Large Quantity Handier did not notify the EPA Regional Administrator to obtain an EPA ID <br />number. <br />80. 66273.33 (CCR) Large Quantity Handler did not manage universal waste according to this section, <br />81. 66273.34 (CCR) Large Quantity Handler did not label universal waste according to this section. <br />82. 66273.35(a) (CCR) Large Quantity Handler had universal waste onsite for more than one year. <br />83. 66273.35(b) (CCR) Large Quantity Handler was unable to demonstrate the length of time the universal waste has <br />been accumulated from the date it became a waste or was received. <br />84. 66273.36 (CCR) Large Quantity Handler did not inform employees who handle universal waste proper handling <br />and emergency procedures <br />85. 66273.39 (CCR) Large Quantity Handler did not keep records of each shipment of universal waste according to <br />this section. <br />86. 66273.82(b) (CCR) Cathode Ray. Tube (CRT) handler that accepts more than 5 CRT devices per calendar year <br />from any offsite source failed to notify DTSC and the CUPA according to section. <br />87. 66273.82(c) (CCR) CRT handler that generates 5,000 kilograms or more of CRT material per calendar year failed <br />to notify DTSC and the CUPA according to this section. <br />OTHER <br />88 See attached "Continuation -Official Inspection Report" for violation(s) not listed above. <br />L3jKN <br />89 25270-25270.13 (HSC) Spill Prevention Control and Countermeasure Plan on site for aboveground <br />petroleum storage tanks). <br />-J71_ R3 Page 7`" of <br />Initialed by Date <br />EHS <br />3/23102 <br />
The URL can be used to link to this page
Your browser does not support the video tag.