My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
3515
>
2200 - Hazardous Waste Program
>
PR0514502
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:43:56 AM
Creation date
11/1/2018 1:07:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514502
PE
2228
FACILITY_ID
FA0003747
STREET_NUMBER
3515
STREET_NAME
NAVY
STREET_TYPE
Dr
City
Stockton
Zip
95203
APN
161-030-02
CURRENT_STATUS
01
SITE_LOCATION
3515 Navy Dr
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\3515\PR0514502\COMPLIANCE INFO 1985 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 1985 - 2016
QuestysRecordDate
8/31/2017 7:31:33 PM
QuestysRecordID
3617636
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY • <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/ <br />HAZARDOUS WASTE PROGRAM INSPECTION REPORT <br />Name: $IIeII Oil <br />Name <br />Fadli 3515 Navy Dr., Stockton <br />Inspection <br />10/08/2010 <br />Add ss: <br />Date: <br />- <br /># V Code S6CtiOD VIOLATIONS <br />T <br />Health & Safe Code; CCR=CA Code of Regulations; V=Violafioni RV=Re at Violation ✓ <br />44 CCR 66265.51 Failed to: (a) prepare a contingency plan; (b) implement contingency plan <br />i i <br />45 CCR 66265.52 Contingency plan incomplete <br />46 CCR 66265.53(a) Contingency plan not on site <br />z <br />47 CCR 66265.55 No emergency coordinator <br />-05 <br />48 CCR 66265.560) Failed to submit written incident report to the Department within 15 days <br />49 CCR 66265.16 Personnel training records incomplete <br />'0 <br />50 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days <br />E <br />51 CCR 66262.34(4)(1) Accumulated more than 6,000 kg of HW onsite at one time <br />Failed to comply with Code of Federal Regulations 262.34(d), (e) & (t) <br />w o <br />m S <br />CFR 262.34(d)(5)(i) No emergency coordinator <br />52 CCR 66262.34(d)(2) CFR 262.34(d)(5)(ii) No modified contingency plan <br />V, <br />CFR 262.34(d)(5)(iii) Failed to train all employees on waste handling and emergency procedures <br />CFR 262.34 d 5 iv Failed to respond to a fire, spill or other release <br />y <br />53 HSC 25244.4 Failed to submit a report to the Department at least every two years <br />N54 <br />HSC 25244.19 Failed to conduct source reductionlevaluation of site and prepare waste minimization plan <br />55 HSC 25244.21 Failed to retain current (SB14) review and plan <br />56 HSC 25160(b)(3) Failed to submit TSDF manifest to the Department for Out -Of -State shipments <br />u. <br />57 CCR 66262.20 Failed to prepare manifests for transportation of hazardous waste <br />C <br />58 CCR 66262.23(a) Failed to: (1) complete, sign or date manifest; (2) obtain dated signature of transporter <br />59 CCR 66262.23(a)(4) Failed to send generator manifest copies to the Department within 30 days <br />of f7 <br />60 CCR 66262.40(a) Failed to keep signed copy for 3 years x <br />ro? <br />vi o <br />61 CCR 66282.42(a) Failed to determine status of hazardous waste when manifest copy not received <br />Wg <br />62 CCR 66262.42(b) Failed to file an exception report <br />H: <br />63 HSC 25160.2(b)(3) Failed to keep a copy of the consolidated manifest for 3 years <br />Q <br />64 CCR 66266.81(a)(4)(B) Failed to retain copy of manifest or bill of lading for spent lead acid batteries <br />Se <br />65 HSC 25160.2(b)(4) Consolidated manifest receipts failed to contain complete information <br />66 HSC 25250.23 Transported used oil and not registered as a hazardous waste hauler <br />c <br />67 CCR 66262.40(c) Failed to retain waste analysis on site for 3 years <br />68 CCR 66262.41(a) Failed to submit Biennial Report to the Department <br />W <br />69 CCR 66262.40(b) Failed to retain copy of Biennial Report/Exception Report for 3 years <br />°C <br />70 CCR 66265.77(a) Failed to report releases to the Department <br />s <br />71 HSC 25160(d) Transported hazardous waste without a manifest <br />72 HSC 25163(a) Transported hazardous waste or transferred HW to a transporter without valid registration <br />g <br />73 HSC 25160.2(c)(2) Offered ineligible waste streams to be transported using consolidated manifest <br />74 CCR 66263.17(a) Transported HW without receiving ID Number and registration cert from DTSC <br />75 CCR 66263.23(b) Delivered hazardous waste to an unauthorized facility <br />76 CCR 66273.32(a) Failed to notify the EPA RA to obtain an EPA ID # prior to accumulating >5000kg of UW <br />77 CCR 66273.32(c) Cathode Ray Tube (CRT) handler failed to notify DTSC 30 days prior to accepting offsite UW <br />78 CCR 66273.33(a) Failed to store UW batteries in a closed container and in a manner that prevents breakage and release to <br />the environment <br />Lu <br />79 CCR 66273.33(b) Failed to: (1) store UW lamps in a closed container and in a manner that prevents breakage and release to the <br />N <br />environment, or 2 immediately dean and containerize any broken lamps or releases to the environment <br />3 <br />Failed to store mercury containing UW in dosed or airtight containers in a manner that prevents breakage <br />80 CCR 66273.33(c) and release to the environment, or failed to immediately clean and containerize any broken mercury <br />Q <br />containinq UW or release to the environment <br />C81 <br />CCR 66273.33.5(a)(1)(B) Failed to: (1) store a UW electronic device in a manner that prevents breakage and release to the environment, or <br />W <br />2 immediately clean and containerize any broken electronic device or release to the environment <br />> <br />62 CCR 68273.33.5(b)(1)(B) Failed to: (1) contain a CRT in a manner that prevents breakage and release to the environment, or (2) <br />immediately clean and containerize any broken CRT or release to the environment <br />83 CCR 66273.34 Failed to label universal waste to identify type of universal waste. (a) Batteries, (b) Mercury containing <br />equipment, c Lamps, tl Electronic devices, a CRTs, CRT glass <br />84 CCR 66273.35 (a) Stored UW onsite for more than 1 year, or (b) was unable to demonstrate the length of time the UW has <br />been accumulated from the date it became a waste or was received <br />85 CCR 66273.39 Failed to keep records of each shipment of universal waste according to this section <br />999 Other: See attached "Continuation - Official Inspection Report" for violation(s) not listed above. <br />UIC Septic System: - Serves > 20 personslday ❑ Receives other than sanitary waste ' I Dry wells/French Drains Onsite <br />i� or Phone:46 <br />` <br />� 209 8-9848 <br />Received <br />IV14 <br />Title: <br />%j v I S ot/t <br />2 <br />By: V4-- <br />✓ <br />EHD 22-02-004 Rev 01/8/10 Page 2 HW INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.