My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1130
>
2200 - Hazardous Waste Program
>
PR0514050
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2019 1:10:45 PM
Creation date
11/1/2018 1:46:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514050
PE
2229
FACILITY_ID
FA0003741
FACILITY_NAME
JIFFY LUBE #598
STREET_NUMBER
1130
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
15120405
CURRENT_STATUS
01
SITE_LOCATION
1130 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1130\PR0514050\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
8/16/2018 10:05:10 PM
QuestysRecordID
3683355
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Hazardous Waste Tank System October <br /> Final Written Assessment per CCR Title 22 <br /> Jiffy Lube Store#598, 1130 North Main Street, Manteca, CA 95336 2017 <br /> cat-cups forum a i d a n c e <br /> Title 22,66265.192(kx I)--A drawing of the tank(s)configuration as well as ✓ <br /> description of the materials of construction and gross capacity is included <br /> (kx2)—Design standards,if available,for the tanks and ancillary equipment,as <br /> well as the following: <br /> (A)—The material of construction <br /> (B)—The material thickness and method used to determine the thickness �C <br /> (C)--Description of tank system piping(material,diameter) <br /> (D)-Description of any internal and external pumps r <br /> (E)--sketch of drawing of tank(s)including dimensions <br /> (k)(3)--Documentcd(or estimated,if unknown)age of the tank system- <br /> (k)(4)--Dcscription and evaluation of any leak detection equipment <br /> (Not applicable if the tank system and associated piping is to be inspected <br /> daily for leaks and corrosion) 1 <br /> (kx5)~Description and evaluation of any corrosion protection <br /> equipment,devices of materials rr <br /> (k)(6)--Description and evaluation of any spill prevention or overfill equipment <br /> (k)(7)--Description and evaluation of the secondary containment <br /> for the tank system(including ancillary equipment)6 <br /> (k)(8)--Hazardous waste characteristics of the waste(s)that have ✓ <br /> been or will be handled is included <br /> (k)(9)--Independent,qualified professional engineer's inspection of the system <br /> for the following; <br /> (A)Weld cracks or breaks <br /> (B)Scrapes of protective coatings ✓ <br /> (C)Corrosion t� <br /> (D)Any structural damage or inadequacy construction or <br /> installation cracks,punctures damaged fittings. All discrepancies shall <br /> be documented in the assessment and remedied before <br /> the tank system is placed in use <br /> k(10)--Ali new tanks and ancillary equipment shall be tested for <br /> tightness prior to being placed in use.The results of the test(s)shall be <br /> documented in this assessment <br /> k(1 I)--Estimated remaining service life of the tank system based on yr <br /> findings of subsections k(I)through k(10) <br /> Strandberg Associates 1(866) 388-0404 rwaterguyQrwaterguy.corn 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.