<br />   	Program 	Permit       														Permit
<br />   	Record ID       —Nuinbi;r   -P{Ogram Code and Description 											Valid
<br />	gRb514244    PT0010447  2220-SMALL ,      TITY HAZARDOUS WASTE GENERATOR FACILITY			1/1/2010 To 12/31/2010
<br />	Hg  ideas Waste Generator Program: .
<br />	In order to maintain the permit to operate, Hazardous Waste Generators shall comply with California Health and Safety Code, Div.20,Chap.6.5,Art.2-13,
<br />	Sec.25100 et seq,_and Title 22,California Code of Regulations,Chap.20_
<br />    							----  	------  			---------------------------    		- - ------------------------
<br />	PR0232523  		2300-UNDERGROUND STORAGE TANK FACILITY       					1/1/2010 To 12/31/2010
<br />	Underground Storage Tank Program:
<br />	California Health and Safety Code,Div.20,Chap._6.7_and Title 23,California Code_of Regulations,Chap__16_
<br />  	--------- ----------- - ------  	---------------       								----- - ------- -------- --------- ------------
<br />  	P/E  Tank#       Tank Record ID	Permit#    Capacity  	Contents   	Permit Status	System Type   	Leak Detection
<br />	2362      1      390002325230252301   PT0005088   20,000   	DIESEL  	Active,billable      DOUBLE WALLED     Continuous Interstitial Monitoring
<br />	2360     2     390002325230252302   PT0005089   20,000   	DIESEL  	Active,billable      DOUBLE WALLED     Continuous Interstitial Monitoring
<br />	2360     3     390002325230252303   PT0005090    550     	OTHER  	Active,billable      DOUBLE WALLED     Continuous Interstitial Monitoring
<br />	2360     4     390002325230252304   PT0005091     550     	OTHER  	Active,billable      DOUBLE WALLED     Continuous Interstitial Monitoring
<br />     	Underground Storage Tank Permit Conditions
<br /> 	1)   The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions.
<br />	2)   In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions
<br />     	established by San Joaquin County.
<br />	3)   If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both
<br />     	the Tank Owner and tank Operator receive a copy of the permit.
<br />	4)   Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Pennit Conditions. The approved
<br />     	monitoring,response,and plot plans shall be maintained onsite with the permit.
<br />	5)   The Pennittee shall comply with the monitoring procedures referenced in this permit.
<br />	6)  The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and
<br />     	provide documentation of such servicing to this office.
<br />	7)  In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the requirements of Title 23 CCR,Chap. 16,Art.5,and the approved Emergency Response Plan.
<br />	8)   Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was
<br />     	performed.
<br />	9)   The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change.
<br />	10)  Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or
<br />     	revocation.
<br />	11)  Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment.
<br />	12)  The Permittee shall submit an annual report documenting compliance with the UST Permit Conditions within 30 days of the date of the issuance of this permit.
<br />	13)  This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency.
<br />	14)  A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated.
<br /> 							PERMITS TO OPERATE are NOT TRANSFERABLE
<br />   							and may be SUSPENDED or REVOKED for cause.
<br />       			PERMIT(s)Valid only for:      SUPER STORE INDUSTRIES
<br />      					Tank Owner:       SUPERSTORE INDUSTRIES
<br />    						THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES
<br />   	Regulated Facility:   SUPER STORE INDUSTRIES*       							Facility ID FA0003833
<br />      			16888 S MCKINLEY AVE     								Account ID AR0003421
<br />      			LATHROP CA 95330     									Issued 2/10/2010
<br />     	Billing Address:
<br />      			SUPER STORE  INDUSTRIES*
<br />      			PO  BOX  549
<br />      			LATHROP   CA   95330
<br />	7023.rpt