Laserfiche WebLink
Sites. In MGP USA:Third International Symposium and Exhibition on the <br /> • Pump Placement. The sorbent tube should be upstream of the sampling pump. Redevelopment of Manufactured Gas Plant Sites.September 23-25,Mystic,CT. <br /> http�//www coalab comINews/Naphthalene-Air-5amplinp odf <br /> • Sample Collection Flow Rate. The flow rate for sample collection should not vary by <br /> more than ten percent. Hayes,H., D. Benton,S.Grewal,and N.Khan. 2007. Evaluation of Sorbent <br /> Methodology for Petroleum-Impacted Site Investigations. In Proceedings;Air and Waste <br /> • Sorbent Tube Orientation. For thermal desorption methods,the sorbent tube must Management Association's Symposium:Vapor Intrusion:Learning from the Challenges. <br /> be oriented in the appropriate direction during sample collection,which is usually September 26-28,2007, Providence,RI <br /> annotated on the tube by the sorbent manufacturer or laboratory. http�// w airtoxigs comlliterature/i)aperslAWMA VI 2007.1)d <br /> • Field Documentation.Field data sheets should be completed in the field and Hayes,H.,D. Benton,S.Grewal,and N.Khan. 2005. A Comparison betweerPA <br /> submitted to the analytical laboratory. The sheets should contain the sampling flow Compendium Method TO-15 and EPA Method 82608 for VOC Determination in Soil <br /> rates and sampling volumes required to quantify contaminant concentrations.These Gas. In Proceedings;Air and Waste Management Association's Symposium'Air <br /> field data sheets should be included within the characterization report. Quality Measurement Methods and Technology. April 19-21,2005, San Francisco, <br /> CA. <br /> • Leak Check Compounds.Quantitative leak test compound such as helium can be <br /> used as described in Appendix C. Leak test compounds,such as helium offer a nice Hayes,H.,N.Khan,and D.Benton. 2006. Impact of Sampling Media on Soil Gas <br /> advantage over qualitative leak test compounds(e.g, Freons and alcohols),in that Measurements. In Proceedings;Air and Waste Management Association's Vapor <br /> Intrusion Symposium:The Next Great Environmental Challenge-An Update. <br /> leakage can be quantified and are readily measured on site with a field meter or by a <br /> September 13-15,2006,Los Angeles,CA. Pages fig-83. <br /> stationary laboratory after the soil gas sample is collected.Qualitative leak test <br /> compounds are usually smaller than C7 and are not retained by Tenax. However,If Hayes,H.,Mahfood,J.,Shamory,B.2008.Comparison of EPA Compendium Methods <br /> qualitative leak test compounds are used,the probes will need to be prescreened for <br /> leaks using EPA Methods 5030/8260 prior to Tenax sorbent sampling. If leak test TO-15 and TO-17 for the Measurement Naphthalene in Soil Gas.In Engineers <br /> compounds with carbon range of C7 or greater are used,an elevated concentration Society of Western Pennsylvania Proceeding. <br /> ing. April,2008; <br /> absorbed onto the sorbent tube may elevate the RL or even overload the mass http//www eswo com/brownficlds/program htm#TS4 <br /> spectrometer after desorption, A shut-in test of the above ground apparatus(i.e., McAlary,T.A.,P.Nicholson, H.Groenevelt,and D.Bertrand.2009.A Case Study of <br /> fittings,sorbent lube(s)and lines)downstream from the probe should be performed <br /> Soil-Gas min Silt and Clay-Rich(Low Permeability)Soils. Ground Water <br /> prior to sampling(McAlary,T.et at,2009). <br /> Monitoringg&Remediation.Volume 29,No.1.Pages 144-152. <br /> • Tube Composition. Sorbent tubes composed of metal should be used due to <br /> potential photochemical reactions. However,if only glass sampling tubes are Ouellette, arG. 2004. En Vapor Sampling and Analysis l Lessons Forum SLearned. Presented <br /> available,the tubes should be wrapped entirely in aluminum foil during and after at rk Department California;Energy/Petroleum Environmental Research Forum Soil Vapor <br /> sample collection. Workshop. Brea,CaJanuary 27-29,2004. <br /> • DuplicateSamples. Duplicate sorbent tube samples should be collected at a pre- USEPA, 1999:United States Environmental Protection Agency. Determination of <br /> determined frequency,usually at a rate of ten percent of the number of samples. Volatile Organic Compounds in Ambient Air Using Active Sampling onto Sorbent Tubes; <br /> Compendium Method TO-17. Compendium of Methods for the Determination of Toxic <br /> • Trip Blanks. Each shipping cooler should contain a trip blank. The trip blank should Organic Compounds in Ambient Air,Second Edition. Center for Environmental <br /> be a sealed sorbent tube filled with the same sorbent as the sampling tubes Research Information,Office of Research and Development;Cincinnati,Ohio. January <br /> 1999. <br /> pursuant to the field procedures. <br /> [ht[p://www.epa.gov/ttnamtl 1lfiles/a mbienVairtox/to-17r.pdfl <br /> REFERENCES <br /> Fortune,A.,L.Gendron,M.Tuday. 2008. Comparison of Naphthalene Ambient Air <br /> Sampling&Analysis Methods at Former Manufacturing Gas Plant(MGP)Remediation <br /> 12/10/2009 -67- 12/10/2009 -68- <br />