My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ANDERSON
>
925
>
2900 - Site Mitigation Program
>
PR0517512
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2018 6:59:48 PM
Creation date
11/1/2018 3:14:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0517512
PE
2960
FACILITY_ID
FA0013476
FACILITY_NAME
FTG CONSTRUCTION MATERIALS, INC
STREET_NUMBER
925
Direction
W
STREET_NAME
ANDERSON
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
925 W ANDERSON ST
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FGL Environmental • Doc ID: F3REC005.001 <br /> Revision Date: 10/20/00 Page: 1 of 1 <br /> Stockton - Condition Upon Receipt (Attach to COC) <br /> Sample Receipt at STK: <br /> 1. Number of ice chests/packages received: <br /> 2. Were samples received in a chilled condition? Temps: <br /> Acceptable is above freezing to 6° C. Note as AOI (arrived on ice) if chilling was begun for samples received on <br /> same day of sampling. <br /> 3. Do the number of bottles received agree with the COC? Yes No N/A <br /> 4. Were samples received intact? (i.e. no broken bottles, leaks etc.) Yes No <br /> 5. Were sample custody seals intact? N/A Yes No <br /> Sign and date the COC, place in a ziplock and put in the same ice chest as the samples. <br /> Sample Receipt Review completed by(initials): <br /> Sample Receipt at SP: <br /> 1. Were samples received in a chilled condition? Temps: <br /> Acceptable is above freezing to 6°C. If many packages are received at one time check for tests/H.T.'s/rushes/Bacti's to <br /> prioritize further review. Please notify Microbiology personnel immediately of bacti samples received. <br /> 2. Do the number of bottles received agree with the COC? No N/A <br /> 3. Were samples received intact? (i.e. no broken bottles, leaks etc.) es No <br /> 4. Were sample custody seals intact? Yes No <br /> Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification, Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? es No <br /> 2. Did bottle labels correspond with the client's ID's? es No <br /> 3. Were all bottles requiring sample preservation properly preserved? Yes No <:M�> FGL <br /> 4. Were all analyses within holding times at time of receipt? es No <br /> 5. Have rush or project due dates been checked and accepted? / Yes No <br /> Attach labels to the containers and include a copy of the COC for lab de iv <br /> Sample Receipt, Login and Verification completed by(initials): <br /> Discrepancy Documentation: <br /> Any items above which are "No" or do not meet specifications (i.e. temps) must be resolved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> 3012612 <br /> F1'G Construction Materials <br /> STK134515 <br /> Tew�1 �7,-1 1 1 1 1 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.