My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO 2008 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:28:18 PM
Creation date
11/1/2018 3:47:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2008 - 2012
FileName_PostFix
2008 - 2012
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIARING SYSTEM CERTIF . ATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited.• Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br />prepared for each monitoring_ system control panel by the technician who performs the work. A copy of this form must be provided to <br />the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems <br />within 30 days of test date. <br />A. General Information <br />Facility Name: Valley ARCO Bldg. No.: ----------- <br />Site Address: 16 E. Harding Way City: Stockton Zip: 95204 <br />Facility Contact Person: Abraham Contact Phone No.: (209)466-9515 <br />Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing: 04/26/2009 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: Regular <br />Tank ID: Premium <br />x❑ In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />I] In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑Annular Space or Vault Sensor. <br />Model: <br />21 Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑x Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑x Fill Sump Sensor(s). <br />Model: <br />208 <br />❑x Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />D Electronic Line Leak Detector. <br />Model: <br />244-006-5 <br />IRI Electronic Line Leak Detector. <br />Model: <br />244-006-5 <br />IXI Tank Overfill / High -Level Sensor. <br />Model: <br />TLS -350 <br />0 Tank Overfill / High -Level Sensor. <br />Model: <br />TLS -350 <br />❑ Other(specify equipment t e and model in Section E on Pae 2). <br />❑ Other(specify equipment t e and model in Section E on Pae 2). <br />Tank ID: Mid -Grade <br />Tank ID: <br />❑X In -Tank Gauging Probe. <br />Model: <br />MAG -1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />El Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑x Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />IHI Electronic Line Leak Detector. <br />Model: <br />244-006-5 <br />❑ Electronic Line Leak Detector. <br />Model: <br />0 Tank Overfill / High -Level Sensor. <br />Model: <br />TLS -350 <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment t e and model in Section E on Page 2). <br />❑ Other (specify equipment t e and model in Section E on Pae 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑Dis enser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9-10 <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />208 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />renorts. I have also attached a cony of the renort: (check all that annlv): R-1 Svstem <br />Technician Name (print): Keith Huston <br />Certification No.: A27755 <br />Testing Company Name: EPIC Compliance Systems, LLC <br />Signature: <br />License. No.: 880430 <br />Phone No.: 888 -700 -EPIC <br />Testing Company Address: 2400 San Bruno Ave, San Francisco, CA Date of Testing/Servicing: 04/29/2009 <br />UN -036 - 1/4 Page I of 4 Rev. 06/04/01 <br />www.unidocs.org <br />