My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO 2008 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2024 1:28:18 PM
Creation date
11/1/2018 3:47:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO 2008 - 2012
FileName_PostFix
2008 - 2012
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
279
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> S. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps L <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer k Industry Standard ❑ Professional Engineer <br /> Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum SHydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: Equipment Resolution: <br /> Fill Sump Fill Sump# Fill Sump# ! Fill Sump# <br /> Sump Diameter: <br /> Sump Depth: t� <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: Q <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: `� x _ <br /> Condition of sump prior to <br /> testing: <br /> Portion of Sump Tested <br /> Sump Material: <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: ' <br /> Test Start Time: <br /> Initial Reading(Rj): j a <br /> Test End Time: <br /> Final Reading(RF): i< 0,f <br /> Test Duration: -30 <br /> Change in Reading(RF-R,): .. <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: Pass ❑Fail Pass ❑Fail ass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? ..Yes ❑No KYes ❑No AYes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑Yes ❑No 'V NA ❑Yes ❑No PiLNA ❑Yes ❑No "A ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? Axes ❑No ❑NA VYes ❑No ❑NA AYes. ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and %Yes ❑No ❑NA PYes ❑No ❑NA Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testin ? r <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.