Laserfiche WebLink
Water Beards: LG 1 1 Page 1 of 2 <br /> ,'Ve,c:onle i(f Califo rn-L a .. <br /> Issue Date:September 11,1998 <br /> Revision Date:April 28,2005 <br /> Veeder-Root <br /> (originally listed as Marley Pump Co.) <br /> Red Jacket ST 1401L, ST 1801L, CPT, ProLink <br /> AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph at 10 psi* with PD = 100% and PFA = 0%. <br /> Leak rate of 0.2 gph at operating pressure with PD = 100% and PFA = 0%. <br /> Leak rate of 0.1 gph at 1.5 times operating pressure* with PD = 100% and PFA = 0%. <br /> *Since leak rate varies as a function of pressure, this leak rate and pressure were certified u <br /> equivalent leak rate and pressure, in accordance with an acceptable protocol. <br /> Leak 1.5 gph for leak rate of 3.0 gph. <br /> Threshold 0.1 gph for leak rate of 0.2 gph. <br /> 0.047 gph for leak rate of 0.1 gph. <br /> A pipeline system should not be declared tight if the test result indicates a loss that equals c <br /> this threshold. <br /> Applicability Gasoline, diesel, aviation fuel, fuel oil #4, methanol, ethanol, gasoline blends with methanol <br /> ethanol. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized fiberglass and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 172 gallons for leak rate of 3.0 gph. <br /> Capacity Maximum of 163 gallons for leak rates of 0.2 gph and 0.1 gph. <br /> Waiting Time None between delivery and testing. <br /> None between dispensing and testing. <br /> Test Period Response time is 2 to 4 minutes for leak rate of 3.0 gph. <br /> Response time is 2 minutes to 4 hours for leak rate of 0.2 gph. <br /> Response time is 4 minutes to 4 hours, 45 minutes for leak rate of 0.1 gph. <br /> Test data are acquired and recorded by a microprocessor. <br /> Calculations are automatically performed by the microprocessor. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. Recording and display of day, date, and time c <br /> test. <br /> Pump shutdown, message display, and alarm activation if leak is declared. <br /> http://www.waterboards.ca.gov/cwphome/ust/leak—Prevention/lgl13/Vendor_Files/vr mar... 1/23/2008 <br />