My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4445
>
2200 - Hazardous Waste Program
>
PR0513889
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 3:37:32 PM
Creation date
11/1/2018 4:14:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513889
PE
2220
FACILITY_ID
FA0003994
FACILITY_NAME
PERSHING GAS FOR LESS
STREET_NUMBER
4445
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11018006
CURRENT_STATUS
01
SITE_LOCATION
4445 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\P\PERSHING\4445\PR0513889\COMPLIANCE INFO 2003 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2017
QuestysRecordDate
2/7/2018 7:08:06 PM
QuestysRecordID
3150309
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
197
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.oro/ehd <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />PERSHING GAS FOR LESS <br />4445 N PERSHING AVE, STOCKTON <br />January 31, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />101 <br />CCR 66262.12 Managed a hazardous waste without an identification number. <br />This facility's hazardous waste ID number is inactive. A hazardous waste generator shall not treat, store, dispose <br />of, transport or offer for transportation, hazardous waste without a hazardous waste ID number. Go to the DTSC <br />web site hftp:/twww.dtsc.ca.gov/IDManifesVPERMHWID.cfm for the form to reactivate the ID number. <br />Immediately reactivate your EPA ID number and submit evidence to the EHD. <br />This is a minor violation. <br />104 <br />CCR 66262.34(d)(2) No modified contingency plan. <br />An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br />emergency Coordinator on site or on call to coordinate emergency response measures, and the following <br />information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br />extinguishers, spill control equipment, and if present, fire alarm; and the phone number of the fire department, <br />unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br />information by a phone. A form is provided that can be used for this purpose. <br />This was corrected on site. <br />This is a minor violation. <br />105 <br />CCR 66262.34(d)(2) No emergency coordinator. <br />An emergency coordinator is lacking. There must be at least one emergency coordinator on site or on call to <br />coordinate emergency response measures, and the following information must be posted by a phone: the name and <br />phone number of the emergency coordinator; location of fire extinguishers, spill control equipment, and if present, <br />fire alarm; and the phone number of the fire department, unless the facility has a direct alarm. Immediately appoint <br />an emergency coordinator and post the required information by a phone. A form is provided that can be used for <br />this purpose. <br />This was corrected on site. <br />This is a minor violation. <br />302 <br />CCR 66262.34(d)(2) Failed to maintain required emergency equipment. <br />The fire extinguisher near the back comer of the facility has not had an annual maintenance check since July 7, <br />2016. Fire extinguishers need to have a maintenance check once every year. All facilities shall be equipped with an <br />internal communication or alarm system, a device capable of calling outside emergency help, spill control <br />equipment, and decontamination equipment at all times. Immediately ensure the fire extinguisher mentioned above <br />has a maintenance check and provide proof to the EHD. <br />This is a minor violation. <br />FA0003994 PR0513889 SC001 011312018 <br />EHD 22-01 Rev. 092216 Page 4 of 5 Small Quantity Hazardous waste Generator OIR <br />
The URL can be used to link to this page