File No. 20-3978-01.W 1 6 KL E IN E E LID ER <br /> January 8, 1997 <br /> hypodermic needle (syringe), which simultaneously punctures the seals on the stainless steel <br /> drive tip and the septum of the glass sample ampoule. The vacuum in the sample ampoule <br /> draws groundwater through the tip into the glass ampoule. The glass ampoule is then pulled <br /> out of the pipe, disengaging the syringe. The septum in the glass ampoule and drive tip reseals <br /> after the syringe is removed. <br /> To reduce the potential for introducing contaminants into the samples, the drive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate or non-phosphate detergent solution and double rinsed with distilled water <br /> prior to use. The sample probe and filters are cleaned in TSP solution and rinsed with methyl <br /> alcohol followed by a distilled water rinse prior to use. New, factory-sterilized syringe needles, <br /> O-rings, septum's and sample tubes are used for each sample. <br /> B-2.6 Sample Handling <br /> After labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder's <br /> office sample control or to the analytical laboratory. A Kleinfelder chain-of-custody form <br /> accompanies the cooler. The chain-of-custody form includes Kleinfelder's name, address and <br /> telephone number, the employee number of the individual who performed the sampling, the <br /> sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, the sample matrix (soil or water) and the analyses for which the samples are <br /> being submitted, if any. The chain-of-custody form is signed by each person who handles the <br /> samples, including all Kleinfelder employees and the receiving employee of office sample <br /> control or the analytical laboratory when the samples are delivered. <br /> B-2.7 Decontamination of Equipment <br /> To reduce the potential for cross-contamination, augers and associated equipment are steam <br /> cleaned prior to drilling each boring. In addition, sampling equipment is cleaned with a <br /> trisodium phosphate or non-phosphate detergent wash and rinsed with distilled water prior to <br /> collecting each soil sample. <br /> B-2.8 Soil Boring Closure and Cutting Disposal <br /> Soil borings are closed immediately after the collection and logging of soil samples. Closure is <br /> accomplished by grouting the boring with a cement/bentonite slurry or as otherwise required. <br /> Drill cuttings will be placed in 55-gallon drums wrapped in plastic or spread around the boring <br /> and left on site for disposal by the site owner. If requested, Kleinfelder can coordinate disposal <br /> of soil and water after analytical results are available. <br /> 10-3978-01.W161207PE014 Page 8-3 Copyright 1997, Kleinfelder, Inc. <br />