SAN J O A Q U I N Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WEST LANE CHEVRON 9484 WEST LN, STOCKTON November 13, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone:the name and phone number of the emergency coordinator; location of fire <br /> extinguishers,spill control equipment, and if present, fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This was corrected on site. <br /> This is a repeat violation,Class II. <br /> 110 CCR 66262.40(a)Failed to keep signed copy of manifests from the designated facility for three years. <br /> Copies of uniform manifests for the disposal of hazardous waste for the last three years were not found on site. <br /> Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and all receipts <br /> used in a consolidated manifesting procedure on site for three years and have them readily available for review. <br /> Immediately locate a copy of all manifests and receipts for the last three years, maintain them on site,and submit <br /> copies to the EHD. <br /> This is a Class II violation. <br /> 403 CCR 66262.34(d)(2)Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> The 5 gallon white bucket containing waste absorbent was observed with no lid. All hazardous waste containers <br /> shall be closed at all times except when adding or removing waste. Immediately close these containers and ensure <br /> all hazardous waste containers are closed when not adding or removing waste. <br /> This is a repeat violation,Class II. <br /> 605 CCR 66262.34(f)Failed to completely label containers or portable tanks of hazardous waste. <br /> The label on the 55 gallon black steel drum containing oily solids were observed without an accumulation start date. <br /> The 55 gallon blue steel drum containing liquid was observed without the physical state, and hazardous properties <br /> identified. All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition(Contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all containers are marked with all the required information. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0004525 PR053n7 SCO01 11/1312017 <br /> EHD 22-01 Rev.09@2116 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 46834201 F 209 464-0138 1 www.sjoehd.com <br />