My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2200 - Hazardous Waste Program
>
PR0514283
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 3:43:23 PM
Creation date
11/2/2018 9:18:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0514283
PE
2220
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\Y\YOSEMITE\1434\PR0514283\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
7/7/2017 9:46:40 PM
QuestysRecordID
3489124
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> SAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 E. Hazelton Ave. • Stockton,CA 95205-6232 to Phone(209) 468-3420 <br /> Donna Heran,R.E.H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit - Permit <br /> Record ID Number Program Code and Description Valid <br /> PRO514283 PT0010486 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 111/2013 To 12/31/2013 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20,Chap.6.5,Art.2-13, <br /> Sec.25100 at seq and Title 22,California Code of Regulations,Chap.20. <br /> PR0231465 2300-UNDERGROUND STORAGE TANK FACILITY 1/1/2013 To 12131/2013 <br /> Underground Storage Tank Program: <br /> California Health and Safety Code,-Div.-_20,-Cl6-1-a-ml Title 23,California Code of Regulations,Chap. 16. ..---_------------_-----. <br /> PIE Tank# - Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection <br /> 2362 4 390002314650146504 PT0004473 12,000 REGULAR UNLEADED Active,billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> 2360 5 390002314650146505 PT0004483 10,000 MIDGRADE UNLEADED Active, billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> 2360 6 390002314650146506 PT0004485 8,000 PREMIUM UNLEADED Active,billable DOUBLE-WALL Continuous Interstitial Monitoring <br /> BOE ID#; 44038440 <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST systerni fails to remain in compliance with these Permit Conditions. <br /> 2) , In order to maintain the operating permit,the owner and operator shall comply with the H&S Code,Div.20,Chap.6.7 and 6.75;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Opemter(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operator of the tank,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. - <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit. <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. - <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Perrnilee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the dale the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 11) Construction,repair and/or removal permits are required from the EFm prior to any change,repair or removal of UST system equipment. <br /> 12) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 13) A"Conditional'Permit may be revoked if corrections specified on the inspection report are not completed by the dam(s) indicated. <br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s) Valid only for: TOWER ENERGY GROUP <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> TOWER MART#886 FacilitylD FA0003739 <br /> Regulated Facility: 1434 W YOSEMITE AVE Account lD <br /> AR0008444 <br /> MANTECA CA 95336 Issued 2119/2013 <br /> Billing Address: ATTN TOWER ENERGY GROUP <br /> TOWER MART #886 <br /> 1983 W 190TH ST STE 100 <br /> TORRANCE CA 90504 <br /> 7023.rpt <br />
The URL can be used to link to this page
Your browser does not support the video tag.