My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
30600
>
2300 - Underground Storage Tank Program
>
PR0231998
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 9:20:38 AM
Creation date
11/2/2018 10:38:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231998
PE
2381
FACILITY_ID
FA0003643
FACILITY_NAME
CHEM-AWAY, INC
STREET_NUMBER
30600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25310015
CURRENT_STATUS
02
SITE_LOCATION
30600 S CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� STATE OF CALIFORNIA .. <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION -FORM B , <br /> I <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT Q 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ® B TANK REMOVED <br /> DBAOR FACILITY NAME WHERE TANK IS INSTALLED: /Ie.+hkr ptb= f <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.M /K4lk B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) P-�"t'V D. TANK CAPACITY IN GALLONS: LIVVVfV <br /> II.TANK CONTENTS IF A-1 1S MARKED,COMPLETEITEMITEM C. <br /> A 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. n-� 1a REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AWATIONGAS <br /> 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT 12�ib PREMNM UNLEADED ❑ 4 GASNOL ❑ 7 METHANOL <br /> ❑ lc MIDGRADE UNLEADED 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICALPRODUCT ❑ 9S UNIPIOVM ❑l 2 WA((STTE .�A,Iy❑ 2 LEADED 89 OTHER(DESCRIBE IN REM D.eE10Y✓) <br /> D. IF(At)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED 14AIUS-e4./ fAil — C.AS.M: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR UNER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM13- 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK z 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ B POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Plimmy T-k) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING 1 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 10D% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP O 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ��ff <br /> PROTECTION E::] 5 CATHODIC PROTECTION IN 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BIC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 �M LANE LEAK ❑2 LANE 71x8 W ❑3 ca+lNuous wrERsnTlu ❑4 EtECIRGNG uN ❑s Al1foMA7K:wrs ❑ 99 OTHER <br /> bEISC TEflRXi MON? m LEAK9(=t 9NIWWN <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 RECONCILIATIONTIORV ❑ 3 ❑ 4 AUTOMATIC TANK [:]5 �R ❑ 6 TNK <br /> MONITORING GAUGING MONITORING TESTING <br /> ❑ 7 CONTINUOUS INTERSTITIAL ❑ 8 SIR ❑ 9 WEEK LY MANUAL ❑ 10 MOSNTHLY TING TANK E::] 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.EST AT•Er0 DATE wi)SED(MO/DAV/YR) 2.SUBSTANCE REMAININGTED QUANTITY F GALLONS 3 WAINERT MATERIALTANK FILLED ?H YES ❑ NO�( <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME / A DATE <br /> (PRINTEDA6IGNATUPE7 AA� 11 11_'7 <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW L <br /> COUNTY# JURISDICTION 9 FACILITY# TANK# <br /> STATE I.D.# No 1 <br /> PERMIT NUMBER PERMIT APPROVED BYLDATE PERMIT EXPIRATION DATE 8 <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLA? E THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UE' GROUND STORAGE TANK REGULATIONS <br /> FORMS (6-95) we FOR00346117 <br />