My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
U
>
UNDINE
>
7761
>
2300 - Underground Storage Tank Program
>
PR0500400
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2024 11:12:41 AM
Creation date
11/2/2018 3:05:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0500400
PE
2333
FACILITY_ID
FA0004749
FACILITY_NAME
ABF FARM SERVICES INC
STREET_NUMBER
7761
Direction
W
STREET_NAME
UNDINE
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
18920006
CURRENT_STATUS
02
SITE_LOCATION
7761 W UNDINE RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\U\UNDINE\7761\PR0500400\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/14/2012 8:00:00 AM
QuestysRecordID
180906
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN.) WATER RESOURCES CONTR,_,;BOARD <br /> FORM `B': ' . UNDERGROUND STORAGE TANK PROGRAM <br /> TANK. � TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> IO <br /> MARK ONLY ❑1 NEW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION El7 PERMANENTLY CLOSED 7 <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT F-16 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: n/ .j�/4? ZQ 6RM TANK-YES NO ❑ n] <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY C> <br /> CD <br /> A. OWNERS TANK IDM B. MANUFACTURED BY; <br /> C. YEAR INSTALLED U _ D. TANK CAPACITY W GALLONS: CJ c) <br /> 11. TANK CO TENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITE D. <br /> A. MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ffT2 LEADED ❑ 3 DIESEL <br /> 3 CHEMICAL PRODUCT ❑ 4 OIL ODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D.BELOW( <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED a C.A.S.0 C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN 13OX A,B,C.a D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑1 STEEUIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE <br /> !MATERIAL <br /> El POLYVINYLCHLORIDE ❑ 7 ALUMINUM 9 10094ME7HANOLCOMPATIBLE FRP <br /> .. � ' <br /> ❑9 BRONZE ❑ 10 GALVANIZEDSTEEL E:].95 UNKNOWN ❑99 OTHER <br /> I C.INTERIOR <br /> ❑ 1 RUBBERLINED ❑2 ALKYD LINING ❑3 EPDXYLINING ❑4 PHENOUCLINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> I ❑IS LINING MATERIAL COMPATIBLE WITH 10094 METHANOL? ❑YES ❑NO ❑99 OTHER <br /> D.CORROSION ❑ 1.POLYSHLENE WRAP ❑2 TARORASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASSREINFORCED PLASTIC <br /> PROTECTION. ❑5 CATHODIC PROTECTION ❑94 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELYIRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD WIFRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 ,91 NONE P B 95 UNKNOWN P 5-99-OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 72.ESTIMATEDOUANTITYOF 3. WAS TANK FILLED WITH <br /> STANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> ' GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT, <br /> APPLICANT'S NAME(PRINTED S SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY* JURISDICTION M AGENCY M FACILITY ID N TANK ID N <br /> I E IM40 <br /> O (_:2T<ql I <br /> CURRENT LOCAL AGENCY FAC%ITY ID# r-E APPROVED BY NAME PHONE i WITH AREA CODE <br /> PERMIT NUMBER /L-15' PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> st'/��� <br /> CHECK M PERMIT AMOUNT SURCHARGE AMT. FEE CODE �ECEIPT f BY: <br /> FORM a(6-29.68) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM W HAS BEEN FILED <br /> .� nnrA Danrccmur_ rnnv - . - - <br />