Laserfiche WebLink
SAN JOAQLTIN LOr"`Ar . HEALTH DISTRIC�P <br /> -- - _. <br /> MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> _ - <br /> TANK CONTENTS - TPH G TPH-D TEPH BTX&E CL HC TCL EDB METALS PCB <br /> Waste Product GC-FID CC FID (3550) (8020) (8010) (D H S) (ICI (8270) <br /> 1 -- ( or-1 - -(5030) (5030) (3540) (8240) AES) <br /> LEADED GASOLINE X X X X <br /> ---- - - - --_-- - - ............._...................._......_--.-... _............._......._-------... - - - —...._... ...._...-._.......... <br /> UNL GASOLINE X X <br /> -------------------......... ---...._......._.. <br /> DIESEL X X <br /> KEROSENE X X <br /> UNKNOWN FUEL X -- X ------ X —--- -X --- --X -•------ ------- <br /> ---- ... -......--_--------......... <br /> --..._ <br /> OIL X X <br /> ..........-............ . -- ..... - ........... ................ <br /> CHLOR. SOLVENTS X X <br /> _........_........ <br /> — <br /> NONCHLOR. SOLVTS X <br /> WASTE/USED OIL X X X X X <br /> ------------ <br /> MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY <br /> The following listing of laboratory analyses abbreviations is provided as a guide so that <br /> terminology used will be more familiar. All analyses methods are designated EPA methods as <br /> described in EPA SW 846, Third Edition. Those methods not found in SW 846, are <br /> specifically noted. <br /> TPH G Total Petroleum Hydrocarbon, Gasoline <br /> TPH D Total Petroleum Hydrocarbon, Diesel <br /> TEPH Total Extractable Petroleum Hydrocarbon (8015) <br /> BTX & E (8020) Benzene, Toluene, Xylene & Ethyl Benzene (8020) <br /> CL HC 8010 OR 8290 Chlorinated Hydrocarbon 8010 or 8290 <br /> TEL (DOHS-LUFT Tetraethyl Lead (DOHS-LUST) <br /> EDB (DOHS-AB 1803) Ethylene dibromide (DOHS-AB 1803) <br /> GC FID Gas Chromatography Flame Ionization Detector <br /> ICP-AES OR AA Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br /> Absorption Spectrometry <br /> Method 5030 Purge and Trap Sample Preparation <br /> Method 3550 Sonication Sample Preparation <br /> Method 3540 Soxhlet Sample Preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. <br /> Fused capillary columns are preferred topacked columns; a packed column may be used as a <br /> "first cut" with "dirty" samples or once the hydrocarbons have been characterized and <br /> proper QA/QC is followed. <br /> For Drinking Water Sources EPA recommends that the 500 series for volatile <br /> organics be used in preference to Ehe 600 series because the detection limits are lover and <br /> the QA/QC is better. <br /> EH 23 048 12/88 <br />