My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO 2013 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:23 AM
Creation date
11/2/2018 3:44:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2016
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\COMPLIANCE INFO 2013 - 2016.PDF
QuestysFileName
COMPLIANCE INFO 2013 - 2016
QuestysRecordDate
5/11/2018 4:45:55 PM
QuestysRecordID
3888620
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
163
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.orglehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Emils Liquor and Sports Shop A(idrey 1405 California Street, Escalon Inspection May 6, 2014 <br /> Name. q p p address. Date: y <br /> VIOLATIONS <br /> # C1 C2 FM Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(,pre-January 1, 1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Com <br /> Onsite to conduct a routine Underground Storage Tank (UST) inspection and observe monitoring system <br /> certification conducted today <br /> Class II Violations: 104, 302, 304, 3lq <br /> 104. Some financial responsibility documentation was received by the EHD on 9-5-2014, however, a <br /> complete set of financial responsibility documents has not been submitted to the EHD. Specifically, a <br /> current copy of the Letter from Chief Financial Officer (CFO) was not submitted to the EHD. A blank form <br /> was provided at the time of inspection and an updated copy of the Letter from CFO was provided to the <br /> EHD at the time of inspection. In the future, you may log into CERS to upload the required information, <br /> and submit for review by the EHD. CORRECTED. <br /> 302 & 304. The L4 annular sensor failed to activate an audible and visual alarm when tested and, <br /> therefore, the tank is not monitored. The interstitial space shall be monitored with a monitoring system <br /> connected to an audible and visual alarm system. The technician onsite cleaned the sensor and <br /> retested with passing results. CORRECTED. <br /> 310. Approximately 1-3 cups of liquid was observed in the diesel STP sump. If water could enter into <br /> the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> The technician onsite removed all the liquid from the aforementioned sump and retained the removed <br /> liquid for testing purposes. CORRECTED. <br /> A copy of the Return to Compliance Certification form was submitted to the EHD at the time of <br /> inspection. <br /> Note: Facility operators are required to upload the following UST program documents into the <br /> California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST Certification of <br /> Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if applicable), <br /> UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. After January 1, 2015, noncompliance with this requirement will be a violation. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT Y TIME AT END'S CURRENT HOURLY RATE. <br /> I JI <br /> Inspector: Re ved By: Title' <br /> launaflaoA,-) <br /> EHD 23-02 Rev 04!19!12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.