Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited. Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: TEXACO Bldg.No.: <br /> Site Address: 1405 CALIFORNIA City: ESCALON Zip: 95320 <br /> Facility Contact Person: CHOCO Contact Phone No.: (209) 838-7674 <br /> Make/Model of Monitoring System: GILBARCO EMC Date of Testing(Servicing: 6/29/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicatespecific a ui ment inspected/serviced: _ <br /> Tank ID: 87 Tank ID: 91 <br /> Z In-Tank Gauging Probe Model: MAGA Z In-Tank Gauging Probe. Model: MAGA <br /> Z Annular Space or Vault Sensor. Model: 420 Z Annular Space or Vault Sensor. Model: 420 <br /> Z Piping Sump/Trench Sensor(s). Model: 208 Z Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: LD2000 Z Mechanical Line Leak Detector. Model: FX1 V <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill i High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DSL Tank ID: <br /> Z In-Tank Gauging Probe. Model. MAGA ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Semor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> Z Mechanical Line Leak Detector. Model: FX1V r]Mechanical Line Leak Detector. Model: <br /> ❑Elzetronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> Z Dispenser Containment Floats)and Cham(s). Z Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensods). Model: ❑Dispenser Containment Sensor(s). Model: <br /> E01Shear Valve(s). E]Shea Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chum(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model. ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Float(s)and Chain($). <br /> "lf the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification .I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary o verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable enerating such reports,1 have also <br /> attached a copy of the report;(check all that apply): ❑System set-up ❑Alarm ory report <br /> Technician Name(print): HEATH MCEVER Signature: <br /> Certification No.: A27562 License.No.:--'5236756-UT <br /> Testing Company Name: SST-SERVICE STATION TESTING Phone No.:(209) 465-5577 <br /> Testing Company Address: PO BOX 31465 STOCKTON CA 95213 Date of Testing/Servicing: 6/29/2009 <br /> Page 1 of 3 <br /> Rev(2/08) <br />