My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
INSTALL_1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:36 AM
Creation date
11/2/2018 3:58:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1997
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CAMBRIDGE\16470\PR0231532\INSTALL 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST SYSTEM DRAWING INFORMATION <br /> 1Three complete sets of plans (include manufacturer's specification sheets for proposed equipment to be installed). <br /> 2. ,•� Plans drawn to scale in non-erasable print. <br /> 3. „L Plot plan to show location of tanks and all associated piping. <br /> G. d Striker plates or drop tube-mounted bottom protectors illustrated below all accessible openings. <br /> 5. G( Tank cross-sectional diagram. <br /> 6. OC Detail of tank, associated piping, excavation and cover. <br /> 7. 0( Tank(s) and piping approved by a nationally recognized independent testing organization. (Title 23, Chapter 16, <br /> Article 3, Section 2631 (b) d 26353 <br /> a. Verification of product compatibility with the tank(s), piping, monitoring <br /> device(s), epoxy or silicone glues, etc. <br /> 9. O( Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. <br /> 10. At the installation site, prior to installation, a tightness test shall be performed on both primary (10) and <br /> secondary (2m) containment systems before covering. (Section 2635 (a) (3) b (4)3 <br /> 11. O, Tank integrity test required upon completion of installation with tank in operating condition. Test results to be <br /> submitted directly to PHS-EHD from the testing company or owner of facility. [Health b Safety Code, Division 20, ' <br /> Chapter 6.7, Section 25291 (h)) <br /> 12. TANK COMPOSITION <br /> TANK 301208 x �� .0.7r..•. .. . R. . . 0 0 <br /> CAPACITY /2,000 /Z.000 <br /> MANUFACTURER XErxeD X4rxe3 <br /> COKPOS1710M Fit"'IIRsr A-6ef/4,5 <br /> MODEL <br /> PRODUCT Req• Unl• fi'-e.a+. Cln/• <br /> CORROSION PROTECTION jC,25 J/4st j6e,�;/4s'. <br /> U.L. LISTED yes yes <br /> COMPATIBILITY WITH 100% y�s `/e 4j <br /> METHANOL <br /> 13. TANK(s) TO BE INSTALLED <br /> A. Steel-clad with fiberglass reinforced plastic coatings, composites, or equivalent non-metallic exterior <br /> coatings or coverings. <br /> (1) Tested at the installation site using an electric resistance holiday detector. <br /> _ (2) Vacuum applied to interstitial space. <br /> LX B. Fiberglass <br /> .L. (1) Installation instructions require an air test and soap bubble test prior to installation. <br /> 0{ (2) Vacuum applied to interstitial space. <br /> oC (3) Hydrostatic annular (primary tank pressure test). <br /> C. Non-clad steel tank [Section 2635 (a) (2) (A)I <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, bolts;washers, <br /> etc.). <br /> (2) Field installed cathodic protection systema designed and certified as adequate by'"ra' <br /> corrosion specialist. <br /> (3) Impressed current systema to be inspected no less than every 60 days. <br />