BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARDINAL
>
221
>
2300 - Underground Storage Tank Program
>
PR0503074
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2021 11:45:40 PM
Creation date
11/2/2018 4:08:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503074
PE
2381
FACILITY_ID
FA0005675
FACILITY_NAME
CARDOZA TRUCKING
STREET_NUMBER
221
Direction
N
STREET_NAME
CARDINAL
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
14330013
CURRENT_STATUS
02
SITE_LOCATION
221 N CARDINAL AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CARDINAL\221\PR0503074\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
2/27/2012 8:00:00 AM
QuestysRecordID
133203
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
wA <br /> STATE OF CALIFORNI! WATER RESOURCES CONTRO OARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION ` 3 <br /> Z <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. - <br /> 10 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWALPERMIT ❑ 5 CHANGE OF INFORMATION7 PERMANENTLY CLO <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE B TANK REMOVE <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 27_1 G C FARM TANK-YES❑ NO W <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY � <br /> A. OWNERS TANK ID R B. MANUFACTURED BY: W <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 1.2 0 ilop <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. [3yi MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL E91 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED d C.A.S.8 C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C.&D <br /> A. TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> F-11 STEEL/IRON E:]2 STNTEEL F-1NLESSS3 FIBERGLASS ❑4 STEEL CLAD W/RBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑B 100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑10 GALVANIZED STEEL [—]95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RUBBERUNEO ❑2 ALKYD UNING ❑3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYEOILENE WRAP ❑2 TAR OR ASPHALT ❑3 VINYL MNP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHDDIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P B 3VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P 8 7 PRESSURE TESTING P 8 91 NONE P B 95 UNKNOWN ■ 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION k AGENCY X FACILITY ID K TANK ID N <br /> CURRENT LOCAL AGENCY FACILITY ID S APPROVED BY NAM[ PHONE F WITH AREA CODE \ <br /> E-4l czZ <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE L <br /> CHECK F PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT F <br /> J/ v <br /> MRM O Io-2-enl THIS FORM MUST BE ACCOMPANIED B Pd FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS RFFN FILED <br />